Myocardial Structural and Functional Response After Long-Term Mechanical Unloading With Continuous Flow Left Ventricular Assist Device: Axial Versus Centrifugal Flow.
- Source :
-
JACC. Heart failure [JACC Heart Fail] 2016 Jul; Vol. 4 (7), pp. 570-576. Date of Electronic Publication: 2016 May 11. - Publication Year :
- 2016
-
Abstract
- Objectives: The aim of this study was to assess the impact of continuous-flow left ventricular assist device (LVAD) type-axial flow (AX) versus centrifugal flow (CR)-on myocardial structural and functional response following mechanical unloading.<br />Background: The use of continuous-flow LVADs is increasing steadily as a therapeutic option for patients with end-stage heart failure who are not responsive to medical therapy. Whether the type of mechanical unloading influences the myocardial response is yet to be determined.<br />Methods: A total of 133 consecutive patients with end-stage heart failure implanted with continuous-flow LVADs (AX, n = 107 [HeartMate II Thoratec Corporation, Pleasanton, California]; CR, n = 26 [HeartWare, HeartWare International, Framingham, Massachusetts]) were prospectively studied. Echocardiograms were obtained pre-LVAD implantation and then serially at 1, 2, 3, 4, 6, 9, and 12 months post-implantation.<br />Results: The 2 pump types led to similar degrees of mechanical unloading as assessed by invasive hemodynamic status and frequency of aortic valve opening. Myocardial structural and functional parameters showed significant improvement post-LVAD in both AX and CR groups. Left ventricular ejection fraction increased significantly from a mean of 18% to 28% and 26% post-LVAD in the AX and CR groups, respectively. Left ventricular end-systolic volume index and left ventricular end-diastolic volume index decreased significantly as early as 30 days post-implantation in the 2 groups. The degree of myocardial structural or functional response between patients in the AX or CR groups appeared to be comparable.<br />Conclusions: Long-term mechanical unloading induced by AX and CR LVADs, while operating within their routine clinical range, seems to exert comparable effects on myocardial structural and functional parameters.<br /> (Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 2213-1787
- Volume :
- 4
- Issue :
- 7
- Database :
- MEDLINE
- Journal :
- JACC. Heart failure
- Publication Type :
- Academic Journal
- Accession number :
- 27179831
- Full Text :
- https://doi.org/10.1016/j.jchf.2016.02.015