Back to Search
Start Over
The influence of deficient retro-aortic rim on technical success and early adverse events following device closure of secundum atrial septal defects: An Analysis of the IMPACT Registry ® .
- Source :
-
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions [Catheter Cardiovasc Interv] 2017 Jan; Vol. 89 (1), pp. 102-111. Date of Electronic Publication: 2016 May 18. - Publication Year :
- 2017
-
Abstract
- Background: Concern regarding aortic erosion has focused attention on the retro-aortic rim in patients undergoing device closure of atrial septal defects (ASD), but its effect on early outcomes is not well studied.<br />Methods: A multicenter retrospective cohort study of patients undergoing device occlusion of ASD between 1/2011-10/2014 was performed, using data from the IMproving Pediatric and Adult Congenital Treatment Registry. Subjects were divided between those with retro-aortic rim <5 and ≥5 mm. Primary outcomes were technical failure and major early adverse events. Case times were measured as surrogates of technical complexity. The effect of deficient retro-aortic rim on primary outcomes was assessed using hierarchical logistic regression, adjusting for other suspected covariates and assessing whether they represent independent risk factors RESULTS: 1,564 subjects (from 77 centers) were included, with deficient retro-aortic rim present in 40%. Technical failure occurred in 91 subjects (5.8%) and a major early adverse event in 64 subjects (4.1%). Adjusting for known covariates, the presence of a deficient retro-aortic rim was not significantly associated with technical failure (OR: 1.3, 95% CI: 0.9-2.1) or major early adverse event (OR: 0.7, 95% CI: 0.4-1. 2). Total case (P = 0.01) and fluoroscopy time (P = 0.02) were greater in subjects with deficient rim, but sheath time was not significantly different (P = 0.07). Additional covariates independently associated with these outcomes were identified.<br />Conclusion: Deficient retro-aortic rim was highly prevalent but not associated with increased risk of technical failure or early adverse events. Studies with longer follow-up are necessary to assess other outcomes, including device erosion. © 2016 Wiley Periodicals, Inc.<br />Competing Interests: The other authors have nothing to disclose.<br /> (© 2016 Wiley Periodicals, Inc.)
- Subjects :
- Adolescent
Cardiac Catheterization instrumentation
Child
Child, Preschool
Female
Heart Septal Defects, Atrial diagnostic imaging
Heart Septal Defects, Atrial epidemiology
Humans
Infant
Infant, Newborn
Logistic Models
Male
Multivariate Analysis
Odds Ratio
Prevalence
Registries
Retrospective Studies
Risk Assessment
Risk Factors
Septal Occluder Device
Time Factors
Treatment Failure
United States epidemiology
Young Adult
Cardiac Catheterization adverse effects
Heart Septal Defects, Atrial therapy
Subjects
Details
- Language :
- English
- ISSN :
- 1522-726X
- Volume :
- 89
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
- Publication Type :
- Academic Journal
- Accession number :
- 27189502
- Full Text :
- https://doi.org/10.1002/ccd.26585