Back to Search Start Over

Triple-site pacing for cardiac resynchronization in permanent atrial fibrillation - Acute phase results from a prospective observational study.

Authors :
Marques P
Nobre Menezes M
Lima da Silva G
Bernardes A
Magalhães A
Cortez-Dias N
Carpinteiro L
de Sousa J
Pinto FJ
Source :
Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology [Rev Port Cardiol] 2016 Jun; Vol. 35 (6), pp. 331-8. Date of Electronic Publication: 2016 May 30.
Publication Year :
2016

Abstract

Introduction and Aim: Multi-site pacing is emerging as a new method for improving response to cardiac resynchronization therapy (CRT), but has been little studied, especially in patients with atrial fibrillation. We aimed to assess the effects of triple-site (Tri-V) vs. biventricular (Bi-V) pacing on hemodynamics and QRS duration.<br />Methods: This was a prospective observational study of patients with permanent atrial fibrillation and ejection fraction <40% undergoing CRT implantation (n=40). One right ventricular (RV) lead was implanted in the apex and another in the right ventricular outflow tract (RVOT) septal wall. A left ventricular (LV) lead was implanted in a conventional venous epicardial position. Cardiac output (using the FloTrac™ Vigileo™ system), mean QRS and ejection fraction were calculated.<br />Results: Mean cardiac output was 4.81±0.97 l/min with Tri-V, 4.68±0.94 l/min with RVOT septal and LV pacing, and 4.68±0.94 l/min with RV apical and LV pacing (p<0.001 for Tri-V vs. both BiV). Mean pre-implantation QRS was 170±25 ms, 123±18 ms with Tri-V, 141±25 ms with RVOT septal pacing and LV pacing and 145±19 with RV apical and LV pacing (p<0.001 for Tri-V vs. both BiV and pre-implantation). Mean ejection fraction was significantly higher with Tri-V (30±11%) vs. Bi-V pacing (28±12% with RVOT septal and LV pacing and 28±11 with RV apical and LV pacing) and pre-implantation (25±8%).<br />Conclusion: Tri-V pacing produced higher cardiac output and shorter QRS duration than Bi-V pacing. This may have a significant impact on the future of CRT.<br /> (Copyright © 2016 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.)

Details

Language :
English; Portuguese
ISSN :
2174-2030
Volume :
35
Issue :
6
Database :
MEDLINE
Journal :
Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology
Publication Type :
Academic Journal
Accession number :
27255170
Full Text :
https://doi.org/10.1016/j.repc.2015.12.006