Back to Search Start Over

Extracting and analyzing ejection fraction values from electronic echocardiography reports in a large health maintenance organization.

Authors :
Xie F
Zheng C
Yuh-Jer Shen A
Chen W
Source :
Health informatics journal [Health Informatics J] 2017 Dec; Vol. 23 (4), pp. 319-328. Date of Electronic Publication: 2016 Jun 07.
Publication Year :
2017

Abstract

The left ventricular ejection fraction value is an important prognostic indicator of cardiovascular outcomes including morbidity and mortality and is often used clinically to indicate severity of heart disease. However, it is usually reported in free-text echocardiography reports. We developed and validated a computerized algorithm to extract ejection fraction values from echocardiography reports and applied the algorithm to a large volume of unstructured echocardiography reports between 1995 and 2011 in a large health maintenance organization. A total of 621,856 echocardiography reports with a description of ejection fraction values or systolic functions were identified, of which 70 percent contained numeric ejection fraction values and the rest (30%) were text descriptions explicitly indicating the systolic left ventricular function. The 12.1 percent (16.0% for male and 8.4% for female) of these extracted ejection fraction values are <45 percent. Validation conducted based on a random sample of 200 reports yielded 95.0 percent sensitivity and 96.9 percent positive predictive value.

Details

Language :
English
ISSN :
1741-2811
Volume :
23
Issue :
4
Database :
MEDLINE
Journal :
Health informatics journal
Publication Type :
Academic Journal
Accession number :
27271114
Full Text :
https://doi.org/10.1177/1460458216651917