Back to Search
Start Over
Safe long-term repeated disruption of the blood-brain barrier using an implantable ultrasound device: a multiparametric study in a primate model.
- Source :
-
Journal of neurosurgery [J Neurosurg] 2017 Apr; Vol. 126 (4), pp. 1351-1361. Date of Electronic Publication: 2016 Jun 10. - Publication Year :
- 2017
-
Abstract
- OBJECTIVE The main limitation to the efficacy of chemotherapy for brain tumors is the restricted access to the brain because of the limited permeability of the blood-brain barrier (BBB). Previous animal studies have shown that the application of pulsed ultrasound (US), in combination with the intravenous injection of microbubbles, can temporarily disrupt the BBB to deliver drugs that normally cannot reach brain tissue. Although many previous studies have been performed with external focused US transducers, the device described in the current work emits US energy using an unfocused transducer implanted in the skull thickness. This method avoids distortion of the US energy by the skull bone and allows for simple, repetitive, and broad disruption of the BBB without the need for MRI monitoring. The purpose of the present study was to determine if the BBB can be safely and repeatedly disrupted using such an implantable unfocused US device in a primate model. METHODS An 11.5-mm-diameter, 1-MHz, planar US device was implanted via a bur hole into the skull of 3 primates (2 Papio anubis [olive] baboons and 1 Macaca fascicularis [macaque]) for 4 months. Pulsed US sonications were applied together with the simultaneous intravenous injection of sulfur hexafluoride microbubbles (SonoVue) every 2 weeks to temporarily disrupt the BBB. In each primate, a total of 7 sonications were performed with a 23.2-msec burst length (25,000 cycles) and a 1-Hz pulse repetition frequency at acoustic pressure levels of 0.6-0.8 MPa. Potential toxicity induced by repeated BBB opening was analyzed using MRI, PET, electroencephalography (EEG), somatosensory evoked potential (SSEP) monitoring, behavioral scales, and histopathological analysis. RESULTS The T1-weighted contrast-enhanced MR images acquired after each sonication exhibited a zone of hypersignal underneath the transducer that persisted for more than 4 hours, indicating a broad region of BBB opening in the acoustic field of the implant. Positron emission tomography images with fluorine-18-labeled fluorodeoxyglucose (FDG) did not indicate any changes in the cerebral metabolism of glucose. Neither epileptic signs nor pathological central nerve conduction was observed on EEG and SSEP recordings, respectively. Behavior in all animals remained normal. Histological analysis showed no hemorrhagic processes, no petechia, and extravasation of only a few erythrocytes. CONCLUSIONS The studies performed confirm that an implantable, 1-MHz US device can be used to repeatedly open the BBB broadly in a large-animal model without inducing any acute, subacute, or chronic lesions.
- Subjects :
- Administration, Intravenous
Animals
Blood-Brain Barrier drug effects
Blood-Brain Barrier pathology
Central Nervous System Agents
Electroencephalography
Equipment Design
Evoked Potentials, Somatosensory
Female
Fluorodeoxyglucose F18
Longitudinal Studies
Macaca fascicularis
Magnetic Resonance Imaging
Male
Microbubbles
Models, Animal
Papio anubis
Positron-Emission Tomography
Radiopharmaceuticals
Sulfur Hexafluoride
Blood-Brain Barrier metabolism
Capillary Permeability drug effects
Ultrasonic Therapy instrumentation
Subjects
Details
- Language :
- English
- ISSN :
- 1933-0693
- Volume :
- 126
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Journal of neurosurgery
- Publication Type :
- Academic Journal
- Accession number :
- 27285538
- Full Text :
- https://doi.org/10.3171/2016.3.JNS151635