Back to Search Start Over

Submerged bed versus unsaturated flow reactor: A pressurized hydrogenotrophic denitrification reactor as a case study.

Authors :
Epsztein R
Beliavski M
Tarre S
Green M
Source :
Chemosphere [Chemosphere] 2016 Oct; Vol. 161, pp. 151-156. Date of Electronic Publication: 2016 Jul 15.
Publication Year :
2016

Abstract

The paper compares the main features of a submerged bed reactor (SuBR) with bubbling and recirculation of gas to those of an unsaturated flow reactor (uSFR) with liquid recirculation. A novel pressurized closed-headspace hydrogenotrophic denitrification system characterized by safe and economic utilization of H2 gas was used for the comparison. Under similar conditions, denitrification rates were lower in the SuBR as a result of a lower effective biofilm surface area and overall gas-liquid mass transfer coefficient kLa. Similar values of effluent DOC were achieved for both reactors, although effluent suspended solids concentration of the SuBR were substantially higher. On the other hand, the required cleaning frequency in the SuBR was 2.5 times lower. Moreover, the SuBR is expected to reduce the recirculation energy consumption by 0.35 kWh/m(3) treated.<br /> (Copyright © 2016 Elsevier Ltd. All rights reserved.)

Details

Language :
English
ISSN :
1879-1298
Volume :
161
Database :
MEDLINE
Journal :
Chemosphere
Publication Type :
Academic Journal
Accession number :
27424057
Full Text :
https://doi.org/10.1016/j.chemosphere.2016.07.005