Back to Search Start Over

An improved synthesis of the radiolabeled prostate-specific membrane antigen inhibitor, [(18) F]DCFPyL.

Authors :
Ravert HT
Holt DP
Chen Y
Mease RC
Fan H
Pomper MG
Dannals RF
Source :
Journal of labelled compounds & radiopharmaceuticals [J Labelled Comp Radiopharm] 2016 Sep; Vol. 59 (11), pp. 439-50. Date of Electronic Publication: 2016 Jul 29.
Publication Year :
2016

Abstract

The radiosynthesis of [(18) F]DCFPyL on 2 distinct automated platforms with full regulatory compliant quality control specifications is described. The radiotracer synthesis was performed on a custom-made radiofluorination module and the Sofie Biosciences ELIXYS. The radiofluorination module synthesis was accomplished in an average of 66 minutes from end of bombardment with an average specific activity at end of synthesis (EOS) of 4.4 TBq/μmol (120 Ci/μmol) and an average radiochemical yield of 30.9% at EOS. The ELIXYS synthesis was completed in an average of 87 minutes with an average specific activity of 2.2 TBq/μmol (59.3 Ci/μmol) and an average radiochemical yield of 19% at EOS. Both synthesis modules produced large millicurie quantities of [(18) F]DCFPyL while conforming to all standard US Pharmacopeia Chapter <823> acceptance testing criteria.<br /> (Copyright © 2016 John Wiley & Sons, Ltd.)

Details

Language :
English
ISSN :
1099-1344
Volume :
59
Issue :
11
Database :
MEDLINE
Journal :
Journal of labelled compounds & radiopharmaceuticals
Publication Type :
Academic Journal
Accession number :
27470935
Full Text :
https://doi.org/10.1002/jlcr.3430