Back to Search Start Over

Freeze-Drying Process Development and Scale-Up: Scale-Up of Edge Vial Versus Center Vial Heat Transfer Coefficients, K v .

Authors :
Pikal MJ
Bogner R
Mudhivarthi V
Sharma P
Sane P
Source :
Journal of pharmaceutical sciences [J Pharm Sci] 2016 Nov; Vol. 105 (11), pp. 3333-3343. Date of Electronic Publication: 2016 Sep 22.
Publication Year :
2016

Abstract

This report presents calculations of the difference between the vial heat transfer coefficient of the "edge vial" and the "center vial" at all scales. The only scale-up adjustment for center vials is for the contribution of radiation from the shelf upon which the vial sits by replacing the emissivity of the laboratory dryer shelf with the emissivity of the production dryer shelf. With edge vials, scales-up adjustments are more complex. While convection is not important, heat transfer from the wall to the bands (surrounding the vial array) by radiation and directly from the band to the vials by both radiation and conduction is important; this radiation heat transfer depends on the emissivity of the vial and the bands and is nearly independent of the emissivity of the dryer walls. Differences in wall temperatures do impact the edge vial effect and scale-up, and estimates for wall temperatures are needed for both laboratory and manufacturing dryers. Auto-loading systems (no bands) may give different edge vial heat transfer coefficients than when operating with bands. Satisfactory agreement between theoretical predictions and experimental values of the edge vial effect indicate that results calculated from the theory are of useful accuracy.<br /> (Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1520-6017
Volume :
105
Issue :
11
Database :
MEDLINE
Journal :
Journal of pharmaceutical sciences
Publication Type :
Academic Journal
Accession number :
27666376
Full Text :
https://doi.org/10.1016/j.xphs.2016.07.027