Back to Search
Start Over
Proximal balloon occlusion versus distal filter protection in carotid artery stenting: A meta-analysis and review of the literature.
Proximal balloon occlusion versus distal filter protection in carotid artery stenting: A meta-analysis and review of the literature.
- Source :
-
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions [Catheter Cardiovasc Interv] 2017 Apr; Vol. 89 (5), pp. 923-931. Date of Electronic Publication: 2016 Nov 12. - Publication Year :
- 2017
-
Abstract
- Introduction: Carotid artery stenting (CAS) is typically performed using embolic protection devices (EPDs) as a means to reduce the risk of procedure-related stroke. In this study, we compared procedural morbidity and mortality associated with distal (D-EPD) vs. proximal (P-EPD) protection.<br />Methods: MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials were queried from January 1998 through May 2015. Only studies comparing (D-EPD) and (P-EPD) were included. Two independent reviewers selected and appraised studies and extracted data in duplicate. Random-effects meta-analysis was used to pool outcomes across studies. Heterogeneity of treatment effect among studies was assessed using the I <superscript>2</superscript> statistics. Publication bias was assessed using inspection of funnel plots. The primary endpoints included 30-day mortality and stroke. Secondary endpoints included new cerebral lesions on diffusion-weighted magnetic resonance imaging (DW-MRI) and contralateral lesions on DW-MRI.<br />Results: A total of 12,281 patients were included from 18 studies (13 prospective and 5 retrospective) comparing (D-EPD) and (P-EPD) in the setting of CAS. The mean patient age was 69 years and 64% of patients were male. No evidence of publication bias was detected. There was no significant difference between the two modalities in terms of the risk of stroke (risk difference [RD] 0.0, 95% confidence interval [CI] -0.01 to 0.01) or mortality (RD 0.0, 95% CI -0.01 to 0.01) nor was there any difference in the incidence of new cerebral lesions on DW-MRI or contralateral DW-MRI lesions.<br />Conclusions: In patients undergoing CAS, both D-EPD and P-EPD provide similar levels of protection from peri-procedural stroke and 30 days mortality. © 2016 Wiley Periodicals, Inc.<br /> (© 2016 Wiley Periodicals, Inc.)
Details
- Language :
- English
- ISSN :
- 1522-726X
- Volume :
- 89
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
- Publication Type :
- Academic Journal
- Accession number :
- 27862881
- Full Text :
- https://doi.org/10.1002/ccd.26842