- Objectives/hypothesis: To explore the perioperative utility of three-dimensionally (3D)-printed temporal bone models of patients undergoing repair of lateral skull base defects and spontaneous cerebrospinal fluid leaks with the middle cranial fossa approach.<br />Study Design: Case series.<br />Methods: 3D-printed temporal bone models-based on patient-specific, high-resolution computed tomographic imaging-were constructed using inexpensive polymer materials. Preoperatively, the models demonstrated the extent of temporal lobe retraction necessary to visualize the proposed defects in the lateral skull base. Also preoperatively, Silastic sheeting was arranged across the modeled tegmen, marked, and cut to cover all of the proposed defect sites. The Silastic sheeting was then sterilized and subsequently served as a precise intraoperative template for a synthetic dural replacement graft. Of note, these grafts were customized without needing to retract the temporal lobe.<br />Results: Five patients underwent the middle cranial fossa approach assisted by 3D-printed temporal bone models to repair tegmen defects and spontaneous cerebrospinal fluid leaks. No complications were encountered. The prefabricated dural repair grafts were easily placed and fit precisely onto the middle fossa floor without any additional modifications. All defects were covered as predicted by the 3D temporal bone models. At their postoperative visits, all five patients maintained resolution of their spontaneous cerebrospinal fluid leaks.<br />Conclusions: Inexpensive 3D-printed temporal bone models of tegmen defects can serve as beneficial adjuncts during lateral skull base repair. The models provide a panoramic preoperative view of all tegmen defects and allow for custom templating of dural grafts without temporal lobe retraction.<br />Level of Evidence: 4 Laryngoscope, 127:2347-2351, 2017.<br /> (© 2016 The American Laryngological, Rhinological and Otological Society, Inc.)
- Subjects :
- Adult
Cerebrospinal Fluid Rhinorrhea diagnosis
Cranial Fossa, Middle diagnostic imaging
Female
Follow-Up Studies
Humans
Male
Middle Aged
Retrospective Studies
Temporal Bone diagnostic imaging
Tomography, X-Ray Computed
Treatment Outcome
Cerebrospinal Fluid Rhinorrhea surgery
Cranial Fossa, Middle surgery
Neurosurgical Procedures methods
Printing, Three-Dimensional
Temporal Bone surgery
Subjects
Details
- Language :
- English
- ISSN :
- 1531-4995
- Volume :
- 127
- Issue :
- 10
- Database :
- MEDLINE
- Journal :
- The Laryngoscope
- Publication Type :
- Academic Journal
- Accession number :
- 27933634
- Full Text :
- https://doi.org/10.1002/lary.26438