Back to Search Start Over

The Sonographic Stenosis Index: A New Specific Quantitative Measure of Transplant Hepatic Arterial Stenosis.

Authors :
Le TX
Hippe DS
McNeeley MF
Dighe MK
Dubinsky TJ
Chan SS
Source :
Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine [J Ultrasound Med] 2017 Apr; Vol. 36 (4), pp. 809-819. Date of Electronic Publication: 2016 Dec 28.
Publication Year :
2017

Abstract

Objectives: This study evaluates the sensitivity and specificity of stenosis index (SI), which accounts for the entire spectral Doppler waveform, to detect significant transplant hepatic arterial stenosis.<br />Materials and Methods: In this institutional review board-approved, HIPAA compliant study, we retrospectively analyzed 69 patients who had catheter angiography for suspected transplant hepatic arterial stenosis (THAS) between January 2006 and December 2010; all patients had Doppler ultrasound within 30 days before angiography. Patients with angiographic stenosis requiring intervention were considered positive for THAS. Stenosis index was calculated from each patient's spectral Doppler ultrasound images by obtaining the ratio of the area under the high-frequency signal to low-frequency signal in the spectral Doppler. Resistive index (RI) and pulsatility index (PI) were also calculated. Receiver operator curve analysis was performed and the area under the curve (AUC) was compared among the three metrics.<br />Results: Forty-eight of 69 patients had THAS by angiography requiring intervention; 21patients had no angiographic evidence of THAS. SI was significantly different (P < .001) between patients with THAS (SI = 1.04 ± 0.20) and those without THAS (SI = 1.39 ± 0.30). Stenosis index had an AUC of 0.86 for detecting THAS, which was significantly higher than that from RI (AUC = 0.68, P = .038 for the comparison) and PI (AUC = 0.70, P = .029). For SI < 1.35, the sensitivity for THAS was 94% and specificity was 52%. For RI < 0.5, the sensitivity was 96% and the specificity was 29%.<br />Conclusions: Stenosis index is more accurate than the resistive index and the pulsatility index for detecting transplant hepatic artery stenosis.<br /> (© 2016 by the American Institute of Ultrasound in Medicine.)

Details

Language :
English
ISSN :
1550-9613
Volume :
36
Issue :
4
Database :
MEDLINE
Journal :
Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine
Publication Type :
Academic Journal
Accession number :
28029703
Full Text :
https://doi.org/10.7863/ultra.16.01005