Back to Search
Start Over
Association of Antitachycardia Pacing or Shocks With Survival in 69,000 Patients With an Implantable Defibrillator.
- Source :
-
Journal of cardiovascular electrophysiology [J Cardiovasc Electrophysiol] 2017 Apr; Vol. 28 (4), pp. 416-422. Date of Electronic Publication: 2017 Feb 17. - Publication Year :
- 2017
-
Abstract
- Aims: Antitachycardia pacing (ATP) is an effective treatment for ventricular tachycardia (VT) and can reduce the frequency of shocks in patients with an implantable cardioverter defibrillator (ICD). The association between survival and ATP, as compared to a shock, has not been confirmed in a large patient population. This study aims to determine if patients with an ICD receiving ATP have lower mortality, as compared to those receiving shock.<br />Methods: Sixty-nine thousand three hundred and sixty-eight patients underwent ICD implantation between October 2008 and May 2013 and were enrolled in the remote monitoring network Merlin.netâ„¢ (St. Jude Medical, St. Paul, MN, USA). Patients were categorized into three groups based on the type of ICD therapy received during follow-up: no therapy (N = 47,927), ATP (N = 8,049), and shock (N = 13,392) groups. Survival was determined by linking implant records to the Social Security Death Index.<br />Results: The no therapy (hazard ratio [HR] 0.60, 95% confidence interval [CI] 0.56-0.64, P < 0.001) and ATP (HR 0.70, 95% CI 0.64-0.77, P < 0.001) groups were associated with a lower mortality risk than the shock group. These results were unaffected by age, gender, device type, atrial fibrillation (AF) burden, or ventricular rate. ATP was effective in 85% of episodes and ATP effectiveness was dependent on the ventricular rate.<br />Conclusions: Mortality rates were higher in ICD patients who received only ATP compared to no therapy, but ICD patients who received a shock had higher mortality compared to both groups. Furthermore, the data suggest that age, gender, device type, AF burden, and rate of arrhythmia do not change the trend of higher mortality in patients receiving ICD shock compared to ATP alone.<br /> (© 2017 Wiley Periodicals, Inc.)
- Subjects :
- Adolescent
Adult
Aged
Aged, 80 and over
Electric Countershock adverse effects
Electric Countershock mortality
Female
Heart Rate
Humans
Kaplan-Meier Estimate
Male
Middle Aged
Proportional Hazards Models
Prosthesis Failure
Retrospective Studies
Risk Factors
Tachycardia, Ventricular diagnosis
Tachycardia, Ventricular mortality
Tachycardia, Ventricular physiopathology
Time Factors
Treatment Outcome
Young Adult
Defibrillators, Implantable
Electric Countershock instrumentation
Tachycardia, Ventricular therapy
Subjects
Details
- Language :
- English
- ISSN :
- 1540-8167
- Volume :
- 28
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Journal of cardiovascular electrophysiology
- Publication Type :
- Academic Journal
- Accession number :
- 28128491
- Full Text :