The Interference Phenomenon of Microcatheters in the Jailing Treatment for Internal Carotid Artery Side Wall Aneurysms with an Open Cell Stent System.

Authors :
Yoo M
Jin SC
Kim SH
Choi BS
Kim HY
Lee S
Kim ST
Jeong HW
Source :
Journal of cerebrovascular and endovascular neurosurgery [J Cerebrovasc Endovasc Neurosurg] 2016 Dec; Vol. 18 (4), pp. 363-368. Date of Electronic Publication: 2016 Dec 31.
Publication Year :
2016

Abstract

Objective: Excelsior XT-27 (Stryker Neurovascular, Fremont, CA, USA) or Rebar 27 (eV3 Covidien, Irvine, CA, USA) microcatheters have recently been used to overcome the limitations of the Renegade Hi-Flo microcatheter such as interference between two microcatheters (one for stent delivery and the other for cerebral aneurysm coiling) during the jailing technique. We evaluated differences and influential factors related to the interference phenomenon according to these two microcatheters group.<br />Materials and Methods: Between June 2011 and September 2013, the jailing technique was applied to 94 internal cerebral artery (ICA) aneurysms. The jailing technique with the Neuroform EZ stent system was performed using Renegade (n = 22), Rebar (n = 35), and XT-27 microcatheters (n = 37). In the Renegade Hi-Flo microcatheter group, the jailing technique was successful in 19/22 patients (86.4%) and interference between the two microcatheters occurred in 6/21 patients (28.6%). In the Rebar and XT-27 microcatheter group, the jailing technique was successful in 71/72 patients (98.6%) and interference between the two microcatheters occurred in 1/72 patients (1.4%).<br />Results: There was a significant difference in the interference between the two delivered microcatheters group ( p -value < 0.000) and the carotid siphon angle ( p -value: 0.004) in the univariate analysis. In the multiple logistic regression analysis, the Rebar and XT-27 microcatheter group (odds ratio [OD] [95% confidence interval (CI)]; 31.277 [3.138-311.729], p -value: 0.003) and the carotid siphon angle (OD [95%CI]; 0.959 [0.922-0.997], p -value: 0.035) were found to be influential factors in the interference phenomenon.<br />Conclusion: The Rebar 27 and XT-27 microcatheters were more successful and exhibited less interference between the two microcatheters than the Renegade Hi-Flo microcatheter.<br />Competing Interests: The authors report no conflict of interest concerning the materials or methods used in this study or the findings specified in this paper.

Details

Language :
English
ISSN :
2234-8565
Volume :
18
Issue :
4
Database :
MEDLINE
Journal :
Journal of cerebrovascular and endovascular neurosurgery
Publication Type :
Academic Journal
Accession number :
28184346
Full Text :
https://doi.org/10.7461/jcen.2016.18.4.363