Everolimus- Versus Novolimus-Eluting Bioresorbable Scaffolds for the Treatment of Coronary Artery Disease: A Matched Comparison.
- Source :
-
JACC. Cardiovascular interventions [JACC Cardiovasc Interv] 2017 Mar 13; Vol. 10 (5), pp. 477-485. Date of Electronic Publication: 2017 Feb 15. - Publication Year :
- 2017
-
Abstract
- Objectives: The purpose of this study was to compare the 1-year outcome of everolimus-eluting bioresorbable scaffolds (eBRS) and Novolimus-eluting bioresorbable scaffolds (nBRS) in patients undergoing percutaneous coronary intervention in a real-life clinical practice scenario.<br />Background: eBRS and nBRS are available and have been proved safe for coronary artery stenting in well-selected patients.<br />Methods: Consecutive patients who underwent bioresorbable scaffold implantation were evaluated retrospectively via 2:1 propensity matching. Target lesion failure comprising cardiac death, target vessel myocardial infarction, and target lesion revascularization was examined after 12 months, along with its individual components as well as scaffold thrombosis.<br />Results: A total 506 patients were available for matching. Of these, 212 eBRS patients (mean age = 62.9 years) and 106 nBRS patients (mean age = 63.1 years) were analyzed after matching. Baseline characteristics and clinical presentation were comparable in both groups. Acute coronary syndromes were present in 53.3% of the eBRS group and in 48.1% of the nBRS group (p = 0.383). Lesion characteristics were also similar. Pre-dilation (99.5% vs. 98.1%; p = 0.218) and post-dilation (84.4% vs. 86.8%; p = 0.576) were performed in the same proportion of matched eBRS and nBRS patients, respectively. The 1-year rates of target lesion failure (4.7% vs. 4.5%; p = 0.851), target lesion revascularization (2.6% vs. 3.5%; p = 0.768), cardiac death (1.5% vs. 2.0%; p = 0.752), and definite scaffold thrombosis (2.0% vs. 1.0%; p = 0.529) did not differ significantly between the eBRS and nBRS groups.<br />Conclusions: The present study reveals comparable clinical results for the 2 types of bioresorbable scaffolds when used during routine practice, but further evidence from randomized controlled trials is needed.<br /> (Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Acute Coronary Syndrome diagnostic imaging
Acute Coronary Syndrome mortality
Aged
Cardiovascular Agents adverse effects
Coronary Artery Disease diagnostic imaging
Coronary Artery Disease mortality
Coronary Thrombosis etiology
Everolimus adverse effects
Female
Humans
Kaplan-Meier Estimate
Macrolides adverse effects
Male
Matched-Pair Analysis
Middle Aged
Myocardial Infarction etiology
Percutaneous Coronary Intervention adverse effects
Percutaneous Coronary Intervention mortality
Prosthesis Design
Registries
Risk Factors
Time Factors
Treatment Outcome
Absorbable Implants
Acute Coronary Syndrome therapy
Cardiovascular Agents administration & dosage
Coated Materials, Biocompatible
Coronary Artery Disease therapy
Everolimus administration & dosage
Macrolides administration & dosage
Percutaneous Coronary Intervention instrumentation
Subjects
Details
- Language :
- English
- ISSN :
- 1876-7605
- Volume :
- 10
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- JACC. Cardiovascular interventions
- Publication Type :
- Academic Journal
- Accession number :
- 28216214
- Full Text :
- https://doi.org/10.1016/j.jcin.2016.11.034