Back to Search Start Over

The consistency of myocardial strain derived from heart deformation analysis.

Authors :
Keller EJ
Fang S
Lin K
Freed BH
Smith PM
Spottiswoode BS
Davids R
Carr M
Jolly MP
Markl M
Carr JC
Collins JD
Source :
The international journal of cardiovascular imaging [Int J Cardiovasc Imaging] 2017 Aug; Vol. 33 (8), pp. 1169-1177. Date of Electronic Publication: 2017 Feb 26.
Publication Year :
2017

Abstract

The purpose of this study was to assess the consistency of semi-automated myocardial strain analysis by prototype software across field strengths, temporal resolutions, and examinations. 35 volunteers (48 ± 13 years; 20% women) and 25 patients (54 ± 12 years; 44% women) without significant cardiac dysfunction underwent cine cardiac magnetic resonance imaging (CMR) at 1.5 T with a temporal resolution of 39.2 msec. 34 subjects also underwent imaging at 3.0 T; 16 had repeat examinations within 14 days; and 9 underwent CMR with temporal resolutions of 12.5 and 39.2 msec on the same day. Prototype heart deformation analysis (HDA) software was used to retrospectively quantify strain from segmented balanced steady state free precession (bSSFP) cinegraphic images. Myocardial contours were automatically generated on short axis images and drawn at end-diastole by two independent reviewers on long-axis images. Contours were automatically propagated throughout the cardiac cycle. Global and regional peak systolic strain were compared across observers, field strengths, temporal resolutions, and examinations. Inter-observer agreement was excellent (ICC > 0.87, p < 0.01). Inter-examination variability was low, ranging from 1.7 (1.0-2.4)% to 2.5 (1.9-3.1)%, except for radial strain: 9.2 (7.6-10.5)%. Most global and regional strain values were not significantly different across field strengths and temporal resolutions (p > 0.05). Normal global peak systolic strain values with HDA were -25.0 (-24.0 to -26.1)% (LV circumferential), 60.5 (55.3 to 65.6)% (LV radial), -22.3 (-20.5 to - 24.0)% (LV longitudinal), and -26.0 (-23.8 to -28.2)% (RV longitudinal). HDA prototype software enabled efficient and consistent quantification of myocardial strain from conventional bSSFP cine CMR data, demonstrating clinical feasibility.

Details

Language :
English
ISSN :
1875-8312
Volume :
33
Issue :
8
Database :
MEDLINE
Journal :
The international journal of cardiovascular imaging
Publication Type :
Academic Journal
Accession number :
28239799
Full Text :