Effect of Needle Size in Ultrasound-guided Core Needle Breast Biopsy: Comparison of 14-, 16-, and 18-Gauge Needles.

Authors :
Giuliani M
Rinaldi P
Rella R
Fabrizi G
Petta F
Carlino G
Di Leone A
Mulè A
Bufi E
Romani M
Belli P
Bonomo L
Source :
Clinical breast cancer [Clin Breast Cancer] 2017 Nov; Vol. 17 (7), pp. 536-543. Date of Electronic Publication: 2017 Mar 06.
Publication Year :
2017

Abstract

Introduction: The aim of the present study was to assess the diagnostic accuracy of ultrasound-guided core needle biopsy (US-CNB) of breast lesions, comparing smaller needles (16- and 18-gauge) with the 14-gauge needle, and to analyze the lesion characteristics influencing US-CNB diagnostic performance.<br />Patients and Methods: All the patients provided informed consent before the biopsy procedure. The data from breast lesions that had undergone US-CNB in our institution from January 2011 to January 2015 were retrospectively reviewed. The inclusion criterion was the surgical histopathologic examination findings of the entire lesion or radiologic follow-up data for ≥ 24 months. The exclusion criterion was the use of preoperative neoadjuvant therapy. The US-CNB results were compared with the surgical pathologic results or with the follow-up findings in the 3 needle size groups (14-, 16-, and 18-gauge). The needle size- and lesion characteristic-specific diagnostic accuracy parameters were evaluated. Statistical analysis was performed using a dedicated software program, and P ≤ .01 was considered significant.<br />Results: A total of 1118 US-CNB cases (1042 patients) were included. Of the 1118 cases, 630 (56.3%) were in the 14-gauge group, 136 (12.2%) in the 16-gauge, and 352 (31.5%) in the 18-gauge needle group. Surgery was performed on 800 lesions (71.6%). Of these, 619 were malignant, 77 were high risk, and 104 were benign. The remaining 318 lesions (28.4%) underwent follow-up imaging studies. All the lesions were stable and, therefore, were considered benign. No differences were observed in the diagnostic accuracy parameters among the 3 needle size groups (P > .01). The false-negative rate was greater for lesions < 10 mm (7.2%) (P < .01) but without statistically significant differences among the 3 gauges (P > .01).<br />Conclusion: US-CNB performed with small needles (16 and 18 gauge) had the same diagnostic accuracy as that performed with 14-gauge needles, regardless of the lesion characteristics.<br /> (Copyright © 2017 Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1938-0666
Volume :
17
Issue :
7
Database :
MEDLINE
Journal :
Clinical breast cancer
Publication Type :
Academic Journal
Accession number :
28342776
Full Text :
https://doi.org/10.1016/j.clbc.2017.02.008