Back to Search Start Over

Quantitative Gross and CT measurements of Cadaveric Cervical Vertebrae (C3 - C6) as Guidelines for the Lateral mass screw fixation.

Authors :
Sangari SK
Heinneman TE
Conti MS
Dossous PF
Dillon DJ
Tsiouris AJ
Pyo SY
Mtui EP
Härtl R
Source :
International journal of spine surgery [Int J Spine Surg] 2016 Dec 20; Vol. 10, pp. 43. Date of Electronic Publication: 2016 Dec 20 (Print Publication: 2016).
Publication Year :
2016

Abstract

Background: Lateral mass screw fixation is the treatment of choice for posterior cervical stabilization. Long or misdirected screws carry a risk of injury to spinal nerve roots or vertebral artery. This study was aimed to assess the gross anatomic and CT measurements of typical cervical vertebrae for the selection of lateral mass screws.<br />Methods: Dimensions of the articular pillars were measured on 1) Dry cervical vertebrae with Vernier calipers and 2) Multiplanar reformations of CT scans of the same vertebrae with Viewer software package. The data was statistically evaluated.<br />Results: The transverse diameter of the articular pillars with Vernier calipers varied from 6.0 to 15.4 mm (mean=10.5 mm ± 1.5) and on CT scans ranged from 8.2 - 16.1 mm (mean=11.6 mm ± 1.4). The antero-posterior diameter, an estimate of the screw length by Roy-Camille technique varied from 3.9 to 12.7 mm (mean=8.6 mm ± 1.6) by Vernier calipers and from 6.4 to 13.3 mm (mean=9.1 ± 1.2) on CT scans. The oblique AP diameter, an estimate of screw length by Magerl method varied from 10.8 to 20.3 mm (mean=14.9 mm ± 1.8) by Vernier calipers and from 11.4 to 19.3 mm (mean=14.5 mm ± 1.7) on CT. The CT measurements for height, transverse and AP diameter of the articular pillars were 0.5 - 1.0 mm larger than dimensions by Vernier calipers. No statistically significant difference was observed between the caliper and CT measurements for the oblique AP diameter.<br />Conclusion: CT measurements of the articular pillars may slightly overestimate the desired screw length selected by spine surgeons when compared to actual anatomy. Although means of the articular pillars correspond to the screw lengths used, substantial number of observations below 10 mm for Roy-Camille trajectory and below 14 mm for Magerl trajectory requires careful preoperative planning and intra-operative confirmation to avoid long/misdirected lateral mass screws.<br />Competing Interests: The authors declare that there is no conflict of interests regarding the publication of this paper.

Details

Language :
English
ISSN :
2211-4599
Volume :
10
Database :
MEDLINE
Journal :
International journal of spine surgery
Publication Type :
Academic Journal
Accession number :
28377857
Full Text :
https://doi.org/10.14444/3043