Back to Search
Start Over
Fe 3 O 4 /hydroxyapatite/graphene quantum dots as a novel nano-sorbent for preconcentration of copper residue in Thai food ingredients: Optimization of ultrasound-assisted magnetic solid phase extraction.
- Source :
-
Ultrasonics sonochemistry [Ultrason Sonochem] 2017 Jul; Vol. 37, pp. 83-93. Date of Electronic Publication: 2016 Dec 31. - Publication Year :
- 2017
-
Abstract
- Fe <subscript>3</subscript> O <subscript>4</subscript> /hydroxyapatite/graphene quantum dots (Fe <subscript>3</subscript> O <subscript>4</subscript> /HAP/GQDs) nanocomposite was synthesized and used as a novel magnetic adsorbent. This nanocomposite was characterized using scanning electron microscopy, transmission electron microscopy, Fourier transform infrared spectroscopy, X-ray diffraction, energy dispersive X-ray spectroscopy, and magnetization property. The Fe <subscript>3</subscript> O <subscript>4</subscript> /HAP/GQDs was applied to pre-concentrate copper residues in Thai food ingredients (so-called "Tom Yum Kung") prior to determination by inductively coupled plasma-atomic emission spectrometry. Based on ultrasound-assisted extraction optimization, various parameters affecting the magnetic solid-phase extraction, such as solution pH, amount of magnetic nanoparticles, adsorption and desorption time, and type of elution solvent and its concentration were evaluated. Under optimal conditions, the linear range was 0.05-1500ngmL <superscript>-1</superscript> (R <superscript>2</superscript> >0.999), limit of detection was 0.58ngmL <superscript>-1</superscript> , and limit of quantification was 1.94ngmL <superscript>-1</superscript> . The precision, expressed as the relative standard deviation of the calibration curve slope (n=5), for intra-day and inter-day analyses was 0.87% and 4.47%, respectively. The recovery study of Cu for real samples was ranged between 83.5% and 104.8%. This approach gave the enrichment factor of 39.2, which guarantees trace analysis of Cu residues. Therefore, Fe <subscript>3</subscript> O <subscript>4</subscript> /HAP/GQDs can be a potential and suitable candidate for the pre-concentration and separation of Cu from food samples. It can easily be reused after treatment with deionized water.<br /> (Copyright © 2017 Elsevier B.V. All rights reserved.)
- Subjects :
- Adsorption
Durapatite chemistry
Food Contamination analysis
Graphite chemistry
Hydrogen-Ion Concentration
Magnetite Nanoparticles chemistry
Models, Molecular
Molecular Conformation
Quantum Dots chemistry
Water chemistry
Analytic Sample Preparation Methods methods
Copper chemistry
Copper isolation & purification
Food Ingredients analysis
Solid Phase Extraction methods
Ultrasonic Waves
Subjects
Details
- Language :
- English
- ISSN :
- 1873-2828
- Volume :
- 37
- Database :
- MEDLINE
- Journal :
- Ultrasonics sonochemistry
- Publication Type :
- Academic Journal
- Accession number :
- 28427685
- Full Text :
- https://doi.org/10.1016/j.ultsonch.2016.12.037