Back to Search Start Over

Safety and Efficacy of the Sofia (6F) PLUS Distal Access Reperfusion Catheter in the Endovascular Treatment of Acute Ischemic Stroke.

Authors :
Shallwani H
Shakir HJ
Rangel-Castilla L
Davies JM
Sonig A
Sattur MG
Bendok BR
Snyder KV
Siddiqui AH
Levy EI
Source :
Neurosurgery [Neurosurgery] 2018 Mar 01; Vol. 82 (3), pp. 312-321.
Publication Year :
2018

Abstract

Background: Neuroendovascular intervention has become a key treatment option for acute ischemic stroke. The Sofia (6F) PLUS catheter was designed for neurovascular access for diagnostic or therapeutic interventions.<br />Objective: To report the first series describing use of the Sofia PLUS intermediate/distal access reperfusion catheter in the treatment of acute ischemic stroke.<br />Methods: In this retrospective study, 41 stroke cases were identified in which the catheter was utilized for thrombolysis/thrombectomy. Mean preprocedure National Institutes of Health Stroke Scale score was 16.5 ± 5.2 (range 4-29). Occluded vessels included the M1 segment, M2 segment, internal carotid artery terminus, cervical internal carotid artery, and basilar artery.<br />Results: Successful positioning of the Sofia PLUS catheter near the occlusion site was achieved in 38 (92.7%) of 41 cases in which thrombectomy or thrombolysis was attempted using intraarterial tissue plasminogen activator, a direct aspiration first-pass technique, and/or stent retrieval. A postprocedure thrombolysis in cerebral infarction (TICI) score of 2b/3 was achieved in 37 of 41 cases. Of 15 cases where the Sofia PLUS was used for a direct aspiration first-pass technique, TICI 2b/3 was achieved in 11 (73.3%). In one case where intra-arterial tissue plasminogen activator was used as the only treatment modality, TICI 2a was achieved. No device-related or catheter-related complications were observed. The mean 7-d-postprocedure National Institutes of Health Stroke Scale score among the 39 survivors was 8.5 ± 7.3 (range 0-23).<br />Conclusion: Initial results with use of the Sofia (6F) PLUS for endovascular treatment of acute ischemic stroke have been encouraging. Experience with a larger series is warranted to further evaluate the safety and efficacy of this device and compare it with other reperfusion catheters.<br /> (Copyright © 2017 by the Congress of Neurological Surgeons)

Details

Language :
English
ISSN :
1524-4040
Volume :
82
Issue :
3
Database :
MEDLINE
Journal :
Neurosurgery
Publication Type :
Academic Journal
Accession number :
28431023
Full Text :