Back to Search Start Over

Steady-state pattern electroretinogram and short-duration transient visual evoked potentials in glaucomatous and healthy eyes.

Authors :
Amarasekera DC
Resende AF
Waisbourd M
Puri S
Moster MR
Hark LA
Katz LJ
Fudemberg SJ
Mantravadi AV
Source :
Clinical & experimental ophthalmology [Clin Exp Ophthalmol] 2018 Jan; Vol. 46 (1), pp. 54-61. Date of Electronic Publication: 2017 Jul 20.
Publication Year :
2018

Abstract

Importance: This study evaluates two rapid electrophysiological glaucoma diagnostic tests that may add a functional perspective to glaucoma diagnosis.<br />Background: This study aimed to determine the ability of two office-based electrophysiological diagnostic tests, steady-state pattern electroretinogram and short-duration transient visual evoked potentials, to discern between glaucomatous and healthy eyes.<br />Design: This is a cross-sectional study in a hospital setting.<br />Participants: Forty-one patients with glaucoma and 41 healthy volunteers participated in the study.<br />Methods: Steady-state pattern electroretinogram and short-duration transient visual evoked potential testing was conducted in glaucomatous and healthy eyes. A 64-bar-size stimulus with both a low-contrast and high-contrast setting was used to compare steady-state pattern electroretinogram parameters in both groups. A low-contrast and high-contrast checkerboard stimulus was used to measure short-duration transient visual evoked potential parameters in both groups.<br />Main Outcome Measures: Steady-state pattern electroretinogram parameters compared were MagnitudeD, MagnitudeD/Magnitude ratio, and the signal-to-noise ratio. Short-duration transient visual evoked potential parameters compared were amplitude and latency.<br />Results: MagnitudeD was significantly lower in glaucoma patients when using a low-contrast (P = 0.001) and high-contrast (P < 0.001) 64-bar-size steady-state pattern electroretinogram stimulus. MagnitudeD/Magnitude ratio and SNR were significantly lower in the glaucoma group when using a high-contrast 64-bar-size stimulus (P < 0.001 and P = 0.010, respectively). Short-duration transient visual evoked potential amplitude and latency were not significantly different between the two groups.<br />Conclusions and Relevance: Steady-state pattern electroretinogram was effectively able to discern between glaucomatous and healthy eyes. Steady-state pattern electroretinogram may thus have a role as a clinically useful electrophysiological diagnostic tool.<br /> (© 2017 Royal Australian and New Zealand College of Ophthalmologists.)

Details

Language :
English
ISSN :
1442-9071
Volume :
46
Issue :
1
Database :
MEDLINE
Journal :
Clinical & experimental ophthalmology
Publication Type :
Academic Journal
Accession number :
28600806
Full Text :
https://doi.org/10.1111/ceo.13006