- Background: Quantifying quality of life (QoL) after left ventricular assist device (LVAD) remains challenging. Heart failure (HF)-specific health status measures are ideal for assessing symptoms of HF; however, if patients' QoL is limited by other factors, they may experience improved HF-specific QoL but no concurrent improvement in generic QoL. We sought to examine and predict discrepancies between disease-specific and generic QoL measures after LVAD.<br />Methods: We examined HF-specific and generic QoL with the Kansas City Cardiomyopathy Questionnaire (KCCQ) and EuroQol-5D Visual Analog Scale (VAS), respectively, among 1,888 patients with advanced heart failure who underwent LVAD implantation from 2012 to 2014 as part of the INTERMACS registry.<br />Results: Both measures showed substantial improvement, on average, at 6 months after LVAD, with mean changes of 32.7 ± 25.0 and 27.6 ± 27.4, respectively. Among the 1,539 patients (81.5%) with moderate/large improvement in KCCQ, 334 (21.7%) had discordant changes in generic QoL (i.e., VAS did not substantially increase despite improvement in KCCQ). In a multivariable logistic regression model, baseline VAS score was the strongest predictor of KCCQ-VAS discordance, whereas post-LVAD complications were not significant predictors of discordance.<br />Conclusions: Most patients have major improvements in both HF-specific and generic QoL after LVAD implantation, and discordance in these measures after LVAD is uncommon. When it did occur, discordance was primarily observed in patients who reported good generic QoL on the VAS before LVAD (despite substantial impairment due to congestive HF). These results support the continued use of HF-specific health status measures to monitor QoL before and after LVAD implantation.<br /> (Copyright © 2017 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1557-3117
- Volume :
- 36
- Issue :
- 11
- Database :
- MEDLINE
- Journal :
- The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation
- Publication Type :
- Academic Journal
- Accession number :
- 28662987
- Full Text :
- https://doi.org/10.1016/j.healun.2017.05.023