Back to Search Start Over

Changes in disease-specific versus generic health status measures after left ventricular assist device implantation: Insights from INTERMACS.

Authors :
Nassif ME
Spertus JA
Jones PG
Fendler TJ
Allen LA
Grady KL
Arnold SV
Source :
The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation [J Heart Lung Transplant] 2017 Nov; Vol. 36 (11), pp. 1243-1249. Date of Electronic Publication: 2017 May 20.
Publication Year :
2017

Abstract

Background: Quantifying quality of life (QoL) after left ventricular assist device (LVAD) remains challenging. Heart failure (HF)-specific health status measures are ideal for assessing symptoms of HF; however, if patients' QoL is limited by other factors, they may experience improved HF-specific QoL but no concurrent improvement in generic QoL. We sought to examine and predict discrepancies between disease-specific and generic QoL measures after LVAD.<br />Methods: We examined HF-specific and generic QoL with the Kansas City Cardiomyopathy Questionnaire (KCCQ) and EuroQol-5D Visual Analog Scale (VAS), respectively, among 1,888 patients with advanced heart failure who underwent LVAD implantation from 2012 to 2014 as part of the INTERMACS registry.<br />Results: Both measures showed substantial improvement, on average, at 6 months after LVAD, with mean changes of 32.7 ± 25.0 and 27.6 ± 27.4, respectively. Among the 1,539 patients (81.5%) with moderate/large improvement in KCCQ, 334 (21.7%) had discordant changes in generic QoL (i.e., VAS did not substantially increase despite improvement in KCCQ). In a multivariable logistic regression model, baseline VAS score was the strongest predictor of KCCQ-VAS discordance, whereas post-LVAD complications were not significant predictors of discordance.<br />Conclusions: Most patients have major improvements in both HF-specific and generic QoL after LVAD implantation, and discordance in these measures after LVAD is uncommon. When it did occur, discordance was primarily observed in patients who reported good generic QoL on the VAS before LVAD (despite substantial impairment due to congestive HF). These results support the continued use of HF-specific health status measures to monitor QoL before and after LVAD implantation.<br /> (Copyright © 2017 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1557-3117
Volume :
36
Issue :
11
Database :
MEDLINE
Journal :
The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation
Publication Type :
Academic Journal
Accession number :
28662987
Full Text :
https://doi.org/10.1016/j.healun.2017.05.023