Back to Search
Start Over
Duplex Doppler Sonographic Assessment of the Superior Mesenteric Artery in Patients With Mesenteric Panniculitis.
- Source :
-
Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine [J Ultrasound Med] 2018 Jan; Vol. 37 (1), pp. 165-172. Date of Electronic Publication: 2017 Jul 21. - Publication Year :
- 2018
-
Abstract
- Objectives: We aimed to determine how the hemodynamic parameters of the superior mesenteric artery are affected in mesenteric panniculitis.<br />Methods: Twenty-one patients with a diagnosis of mesenteric panniculitis on computed tomography were evaluated with duplex Doppler sonography. The control group consisted 20 asymptomatic volunteers. The peak systolic velocity, end-diastolic velocity (EDV), resistive index (RI), pulsatility index (PI), blood flow volume, and body mass index were measured in the group of patients with mesenteric panniculitis, and the findings were compared with those of the control group.<br />Results: The mean blood flow volume and EDV were significantly higher in the patient group: The mean superior mesenteric artery blood flow volume ± SD was 917.86 ± 228.97 mL/min in the patient group versus 389.73 ± 92.72 mL/min in the control group (P < .001). The mean EDV was 31.56 ± 8.44 m/s in the patient group versus 19.27 ± 4.19 m/s in the control group (P < .001). The mean RI and PI were significantly lower in the patient group: The mean RI was 0.81 ± 0.04 in the patient group versus 0.85 ± 0.03 in the control group (P = .001). The mean PI was 2.69 ± 0.68 in the patient group versus 3.81 ± 1.13 in the control group (P = .001). the mean superior mesenteric artery diameter was 7.30 ± 0.67 mm in the patient group versus and 6.46 ± 0.66 mm in the control group (P < .001). The mean BMI was 27.95 ± 3.80 kg/m <superscript>2</superscript> in the patient group versus 23.16 ± 3.47 kg/m <superscript>2</superscript> in the control group (P < .001).<br />Conclusions: In patients with mesenteric panniculitis, the Doppler spectrum of the superior mesenteric artery shows detectable changes, which are characterized by decreased vascular resistance and increased blood flow.<br /> (© 2017 by the American Institute of Ultrasound in Medicine.)
- Subjects :
- Adult
Aged
Blood Flow Velocity physiology
Female
Humans
Male
Mesentery diagnostic imaging
Middle Aged
Mesenteric Artery, Superior diagnostic imaging
Mesenteric Artery, Superior physiopathology
Panniculitis, Peritoneal diagnostic imaging
Panniculitis, Peritoneal physiopathology
Ultrasonography, Doppler, Duplex methods
Subjects
Details
- Language :
- English
- ISSN :
- 1550-9613
- Volume :
- 37
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine
- Publication Type :
- Academic Journal
- Accession number :
- 28731594
- Full Text :
- https://doi.org/10.1002/jum.14314