Concordance of Time-of-Flight MRA and Digital Subtraction Angiography in Adult Primary Central Nervous System Vasculitis.
- Source :
-
AJNR. American journal of neuroradiology [AJNR Am J Neuroradiol] 2017 Oct; Vol. 38 (10), pp. 1917-1922. Date of Electronic Publication: 2017 Jul 27. - Publication Year :
- 2017
-
Abstract
- Background and Purpose: 3D-TOF-MRA and DSA are 2 available tools to demonstrate neurovascular involvement in primary central nervous system vasculitis. We aimed to compare the diagnostic concordance of vessel imaging using 3D-TOF-MRA and DSA in patients with primary central nervous system vasculitis.<br />Materials and Methods: We retrospectively identified all patients included in the French primary central nervous system vasculitis cohort of 85 patients who underwent, at baseline, both intracranial 3D-TOF-MRA and DSA in an interval of no more than 2 weeks and before treatment initiation. Two neuroradiologists independently reviewed all 3D-TOF-MRA and DSA imaging. Brain vasculature was divided into 25 arterial segments. Concordance between 3D-TOF-MRA and DSA for the identification of arterial stenosis was assessed by the Cohen κ Index.<br />Results: Thirty-one patients met the inclusion criteria, including 20 imaged with a 1.5T MR unit and 11 with a 3T MR unit. Among the 25 patients (81%) with abnormal DSA findings, 24 demonstrated abnormal 3D-TOF-MRA findings, whereas all 6 remaining patients with normal DSA findings had normal 3D-TOF-MRA findings. In the per-segment analysis, concordance between 1.5T 3D-TOF-MRA and DSA was 0.82 (95% CI, 0.75-0.93), and between 3T 3D-TOF-MRA and DSA, it was 0.87 (95% CI, 0.78-0.91).<br />Conclusions: 3D-TOF-MRA shows a high concordance with DSA in diagnostic performance when analyzing brain vasculature in patients with primary central nervous system vasculitis. In patients with negative 3T 3D-TOF-MRA findings, the added diagnostic value of DSA is limited.<br /> (© 2017 by American Journal of Neuroradiology.)
Details
- Language :
- English
- ISSN :
- 1936-959X
- Volume :
- 38
- Issue :
- 10
- Database :
- MEDLINE
- Journal :
- AJNR. American journal of neuroradiology
- Publication Type :
- Academic Journal
- Accession number :
- 28751515
- Full Text :
- https://doi.org/10.3174/ajnr.A5300