Back to Search Start Over

Long-term Patient-reported Clinical Outcomes and Reoperation Rate after Photovaporization with the XPS-180W GreenLight Laser.

Authors :
Calves J
Thoulouzan M
Perrouin-Verbe MA
Joulin V
Valeri A
Fournier G
Source :
European urology focus [Eur Urol Focus] 2019 Jul; Vol. 5 (4), pp. 676-680.
Publication Year :
2019

Abstract

Objective: To evaluate the long-term reported clinical outcomes after photovaporization of the prostate (PVP) with the XPS-GreenLight laser in patients with symptomatic benign prostatic enlargement (BPE).<br />Design, Setting, and Participants: A prospective longitudinal study was performed for all consecutive patients with BPE who underwent PVP at our institution between 2010 and 2012. Patient-reported clinical outcomes were assessed at 1 mo, 3 mo, 12 mo, and 57 mo using International Prostate Symptoms Score, International Continence Society, and International Index of Erectile Function short-form questionnaires. Maximum flow rate (Qmax), postvoid residual urine measurements were assessed at 3 mo and 12 mo. Long-term satisfaction, complications, and reoperation rates were assessed by questionnaires. Prostate-specific antigen was measured at 3 mo, 12 mo, and 57 mo.<br />Intervention: A single surgeon (GF) has practiced photovaporization with a Moxy fiber, under transrectal ultrasonography monitoring. Long-term clinical outcomes were evaluated using questionnaires.<br />Outcome Measurements and Statistical Analysis: The primary measurement was the reoperation.<br />Results and Limitations: Eighty-four patients of 102 answered the long-term questionnaire. The mean age was 68±7.2 yr. The mean follow-up was 57.4±6.8 mo. The mean prostate volume was 73±38ml. After treatment, the mean International Prostate Symptoms Score decreased significantly from 19.9±6.4 to 6.1±5.6, 3.9±3.4, and 5.9±5.8, respectively, at 3 mo, 12 mo, and 57 mo. The mean prostate-specific antigen level decreased significantly (-56%) from 4.5±4.3ng/ml preoperatively to 2.0±2.0ng/ml and 2.6±2.2ng/ml, respectively, at 12 mo and 57 mo. The mean Qmax increased from 9.6±3.8ml/s preoperatively to 23.9±11.5ml/s and 25.2±9.2ml/s, respectively, at 3 mo and 12 mo. Overall reoperation rate was 4.8%(4/84). Limitations include the single surgeon single center design study and the lack of long-term objectives data such as urodynamic parameters (postvoid residual urine and Qmax).<br />Conclusions: Photovaporization of the prostate with the XPS-GreenLight laser is an effective technique able to durably improve reported clinical outcomes in patients with BPE.<br />Patient Summary: In this study we looked at the long-term outcomes after laser therapy with XPS-GreenLight laser for benign prostatic enlargement. We found a few reoperation rates and good stable reported clinical outcomes after a mean follow-up of 57 mo. We conclude that this laser technique can offer durably good reported clinical outcomes.<br /> (Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
2405-4569
Volume :
5
Issue :
4
Database :
MEDLINE
Journal :
European urology focus
Publication Type :
Academic Journal
Accession number :
29102672
Full Text :
https://doi.org/10.1016/j.euf.2017.10.006