Quality of life and functional capacity outcomes in the MOMENTUM 3 trial at 6 months: A call for new metrics for left ventricular assist device patients.
- Source :
-
The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation [J Heart Lung Transplant] 2018 Jan; Vol. 37 (1), pp. 15-24. Date of Electronic Publication: 2017 Oct 24. - Publication Year :
- 2018
-
Abstract
- Background: The Multicenter Study of MAGLEV Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3 (MOMENTUM 3) clinical trial demonstrated improved 6-month event-free survival, but a detailed analysis of health-related quality of life (HR-QOL) and functional capacity (FC) was not presented. Further, the effect of early serious adverse events (SAEs) on these metrics and on the general ability to live well while supported with a left ventricular assist system (LVAS) warrants evaluation.<br />Methods: FC (New York Heart Association [NYHA] and 6-minute walk test [6MWT]) and HR-QOL (European Quality of Life [EQ-5D-5L] and the Kansas City Cardiomyopathy [KCCQ]) assessments were obtained at baseline and 6 months after HeartMate 3 (HM3, n = 151; Abbott, Abbott Park, IL) or HeartMate II (HMII, n = 138; Abbott) implant as part of the MOMENTUM 3 clinical trial. Metrics were compared between devices and in those with and without events. The proportion of patients "living well on an LVAS" at 6 months, defined as alive with satisfactory FC (NYHA I/II or 6MWT > 300 meters) and HR-QOL (overall KCCQ > 50), was evaluated.<br />Results: Although the median (25th-75th percentile) patient KCCQ (change for HM3: +28 [10-46]; HMII: +29 [9-48]) and EQ-5D-5L (change for HM3: -1 [-5 to 0]; HMII: -2 [-6 to 0]) scores improved from baseline to 6 months (p < 0.05), there were no differences between devices (p > 0.05). Likewise, there was an equivalent improvement in 6MWT distance at 6 months in HM3 (+94 [1-274] meters] and HMII (+188[43-340 meters]) from baseline. In patients with SAEs (n = 188), 6MWTs increased from baseline (p < 0.001), but gains for both devices were less than those without SAE (HM3: +74 [-9 to 183] meters with SAE vs +140 [35-329] meters without SAE; HMII: +177 [47-356] meters with SAE vs +192 [23-337] meters without SAE, both p < 0.003). SAEs did not affect the 6-month HR-QOL scores. The "living well" end point was achieved in 145 HM3 (63%) and 120 HMII (68%) patients (p = 0.44).<br />Conclusions: Gains in HR-QOL and FC were similar early after HM3 and HMII implant. 6MWT improvements were attenuated in patients experiencing SAEs, but HR-QOL metrics did not change. The development of left ventricular assist device-specific HR-QOL tools is needed to better characterize the effect of SAEs on a patient's well-being.<br />Clinical Trial No: MOMENTUM 3 clinical trial #NCT02224755.<br /> (Copyright © 2018 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1557-3117
- Volume :
- 37
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation
- Publication Type :
- Academic Journal
- Accession number :
- 29153637
- Full Text :
- https://doi.org/10.1016/j.healun.2017.10.019