Objective: Stereoelectroencephalography (sEEG) requires extensive preoperative planning to optimize placement of electrodes and limit the potential for complications. Flat-detector computed tomography (FD-CT) has previously been used for perioperative vascular imaging to guide the treatment of vascular lesions. This imaging modality provides a detailed depiction of cerebrovascular and bony cranial anatomy, which can be used to guide intracranial electrode implantation. We have developed a novel method to improve preoperative planning for sEEG electrode implantation and limit the potential for postoperative complications by using FD-CT imaging merged with preoperative magnetic resonance imaging (MRI).<br />Methods: All patients underwent preoperative FD-CT with selective intra-arterial iodinated contrast dye injection through the late arterial and capillary phases for evaluation of cerebrovascular anatomy. These results were merged with thin-cut MRI for trajectory planning of intracranial sEEG electrodes. All patients underwent routine CT and MRI after electrode placement.<br />Results: 39 patients have undergone sEEG implantation according to this protocol, with a total of 541 electrodes placed. Additionally, 25 (64.1%) patients underwent implantation of 70 oblique insular electrodes. There were no clinically significant complications after the implantations. Thirty-six (92.3%) patients underwent operative intervention, including surgical resection in 27 (69.2%) patients.<br />Conclusion: FD-CT imaging allows for a detailed depiction of cortical cerebrovascular anatomy through the capillary phase, in addition to bony cranial anatomy. This enables the safe planning of complex trajectories, including high-obliquity insular electrodes and transsulcal trajectories through "empty sulci" while also providing concurrent imaging of bony anatomy to allow for preoperative planning of drill depth and anchor placement.<br /> (Copyright © 2017 Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1878-8769
Volume :
110
Database :
MEDLINE
Journal :
World neurosurgery
Publication Type :
Academic Journal
Accession number :
29175567
Full Text :
https://doi.org/10.1016/j.wneu.2017.11.063