Back to Search
Start Over
[Comparative study of the serum measurement of PTH on Roche Cobas e411 ® versus the Abbott Architect ci8200 ® ].
- Source :
-
Annales de biologie clinique [Ann Biol Clin (Paris)] 2018 Jan 01; Vol. 76 (1), pp. 61-67. - Publication Year :
- 2018
-
Abstract
- Parathormone (PTH) is the main hormone of phosphocalcic homeostasis. It is synthesized and secreted by the parathyroid glands. PTH has become a routine test in the medical biology laboratory. However, its measurement presents analytical difficulties with the various marketed kits. The aim of this work is to present the results of a comparative study between the PTH measurment on Abbott architect ci8200 and on Roche's Cobas e411 automaton. It is a prospective study carried out for 252 hospitalized patients in the various departments of the University Hospital Center Mohammed VI of Oujda. The "intact" PTH tests were performed on two automata: Abbott Architect ci8200 and Roche Cobas e411. The first uses chemiluminescent microparticle immunoassay. The second uses electrochemiluminiscence sandwich enzyme immunoassay. The agreement of the results between the different techniques was evaluated using the Bland-Altman difference diagram and the Passing-Bablok and Deming regression line (MedCalc software version 14.8.1.0 <superscript>®</superscript> ). By analyzing the diagram of Bland-Altman, we note that the average bias between both methods is of the order of 193.9 pg/mL. As for the equation of the right of Passing-Bablok, it is: Y(Architect) = 3.11 X (Cobas) - 12.26. In conclusion, our study shows a great discrepancy between the results of the PTH assay on the Architect ci8200 versus the Cobas e411, hence the biologist's indisputable role in the control and evaluation of the kits marketed through the various validation tests.
- Subjects :
- Adolescent
Adult
Aged
Aged, 80 and over
Blood Specimen Collection standards
Child
Child, Preschool
Cross-Sectional Studies
Female
Humans
Immunoassay instrumentation
Immunoassay methods
Infant
Infant, Newborn
Male
Middle Aged
Parathyroid Hormone analysis
Radioimmunoassay instrumentation
Radioimmunoassay methods
Reproducibility of Results
Young Adult
Blood Chemical Analysis instrumentation
Blood Chemical Analysis methods
Parathyroid Hormone blood
Subjects
Details
- Language :
- French
- ISSN :
- 1950-6112
- Volume :
- 76
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Annales de biologie clinique
- Publication Type :
- Academic Journal
- Accession number :
- 29243659
- Full Text :
- https://doi.org/10.1684/abc.2017.1309