Back to Search Start Over

Insight into Identification of Acinetobacter Species by Matrix-Assisted Laser Desorption/Ionization Time of Flight Mass Spectrometry (MALDI-TOF MS) in the Clinical Laboratory.

Authors :
Li X
Tang Y
Lu X
Source :
Journal of the American Society for Mass Spectrometry [J Am Soc Mass Spectrom] 2018 Jul; Vol. 29 (7), pp. 1546-1553. Date of Electronic Publication: 2018 Apr 09.
Publication Year :
2018

Abstract

Currently, the capability of identification for Acinetobacter species using MALDI-TOF MS still remains unclear in clinical laboratories due to certain elusory phenomena. Thus, we conducted this research to evaluate this technique and reveal the causes of misidentification. Briefly, a total of 788 Acinetobacter strains were collected and confirmed at the species level by 16S rDNA and rpoB sequencing, and subsequently compared to the identification by MALDI-TOF MS using direct smear and bacterial extraction pretreatments. Cluster analysis was performed based on the mass spectra and 16S rDNA to reflect the diversity among different species. Eventually, 19 Acinetobacter species were confirmed, including 6 species unavailable in Biotyper 3.0 database. Another novel species was observed, temporarily named A. corallinus. The accuracy of identification for Acinetobacter species using MALDI-TOF MS was 97.08% (765/788), regardless of which pretreatment was applied. The misidentification only occurred on 3 A. parvus strains and 20 strains of species unavailable in the database. The proportions of strains with identification score ≥ 2.000 using direct smear and bacterial extraction pretreatments were 86.04% (678/788) and 95.43% (752/788), χ <superscript>2</superscript>  = 41.336, P < 0.001. The species similar in 16 rDNA were discriminative from the mass spectra, such as A. baumannii & A. junii, A. pittii & A. calcoaceticus, and A. nosocomialis & A. seifertii. Therefore, using MALDI-TOF MS to identify Acinetobacter strains isolated from clinical samples was deemed reliable. Misidentification occurred occasionally due to the insufficiency of the database rather than sample extraction failure. We suggest gene sequencing should be performed when the identification score is under 2.000 even when using bacterial extraction pretreatment. Graphical Abstract ᅟ.

Details

Language :
English
ISSN :
1879-1123
Volume :
29
Issue :
7
Database :
MEDLINE
Journal :
Journal of the American Society for Mass Spectrometry
Publication Type :
Academic Journal
Accession number :
29633221
Full Text :
https://doi.org/10.1007/s13361-018-1911-4