Back to Search Start Over

Quantifying the mechanical and histological properties of thrombus analog made from human blood for the creation of synthetic thrombus for thrombectomy device testing.

Authors :
Merritt W
Holter AM
Beahm S
Gonzalez C
Becker TA
Tabor A
Ducruet AF
Bonsmann LS
Cotter TR
Frenklakh S
Source :
Journal of neurointerventional surgery [J Neurointerv Surg] 2018 Dec; Vol. 10 (12), pp. 1168-1173. Date of Electronic Publication: 2018 Apr 25.
Publication Year :
2018

Abstract

Background: Untreated ischemic stroke can lead to severe morbidity and death, and as such, there are numerous endovascular blood-clot removal (thrombectomy) devices approved for human use. Human thrombi types are highly variable and are typically classified in qualitative terms - 'soft/red,' 'hard/white,' or 'aged/calcified.' Quantifying human thrombus properties can accelerate the development of thrombus analogs for the study of thrombectomy outcomes, which are often inconsistent among treated patients.<br />Methods: 'Soft'human thrombi were created from blood samples ex vivo (ie, human blood clotted in sample vials) and tested for mechanical properties using a hybrid rheometer material testing system. Synthetic thrombus materials were also mechanically tested and compared with the 'soft' human blood clots.<br />Results: Mechanical testing quantified the shear modulus and dynamic (elastic) modulus of volunteer human thrombus samples. This data was used to formulate a synthetic blood clot made from a composite polymer hydrogel of polyacrylamide and alginate (PAAM-Alg). The PAAM-Alg interpenetrating network of covalently and ionically cross-linked polymers had tunable elastic and shear moduli properties and shape memory characteristics.<br />Conclusions: Due to its adjustable properties, PAAM-Alg can be modified to mimic various thrombi classifications. Future studies will include obtaining and quantitatively classifying patient thrombectomy samples and altering the PAAM-Alg to mimic the results for use with in vitro thrombectomy studies.<br />Competing Interests: Competing interests: None declared.<br /> (© Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.)

Details

Language :
English
ISSN :
1759-8486
Volume :
10
Issue :
12
Database :
MEDLINE
Journal :
Journal of neurointerventional surgery
Publication Type :
Academic Journal
Accession number :
29695602
Full Text :
https://doi.org/10.1136/neurintsurg-2017-013675