Back to Search Start Over

[Application of Low Concentration Contrast Agent Combined Double Low Dose in CT Pulmonary Angiography for Pulmonary Embolism].

Authors :
Li L
Zhao F
Pu YM
Zhang K
Pu J
Li YM
Peng WL
Zhang JG
Xia CC
Li ZL
Source :
Sichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition [Sichuan Da Xue Xue Bao Yi Xue Ban] 2018 Mar; Vol. 49 (2), pp. 239-242.
Publication Year :
2018

Abstract

Objective: To investigate the feasibility of low concentration contrast agent combined double low dose in CT pulmonary angiography.<br />Methods: 60 patients with clinically suspected pulmonary embolism examed by CT pulmonary angiography (CTPA) were divided into two groups (experimental group: n =30,80 kV, 15 mL,320 mg I/mL;control group: n =30,120 kV,50 mL,370 mg I/mL). The average CT value of main right and left pulmonary arteries,lobar arteries was calculated. Imaging post processing techniques included curved plannar reconstruction (CPR),volume rendering (VR) and maximal intensity projection (MIP). The artifact of the remaining contract in the superior vena cava and overall quality of the image were observed and analyzed by two senior doctors who were double blinded.<br />Results: All patients in two groups completed CTPA successfully. The image qualities of two groupssatisfy clinical diagnostic requirements and no difference of the image qualities was observed between two groups ( P >0.05). The evaluation of venous pollution in experimental group was better than that of control group ( P <0.01).No difference of CT values were observed between two groups [experimental group (423.2±89.4) HU,control group (465.7±85.6) HU]( P >0.05). The SNR and CNR in experimental group were lower than those in control group ( P <0.01 both).The CT dose index volume (CTDIvol),dose-length product (DLP) and size-specific dose estimates (SSDE) in experimental group were significantly lower than those incontrol group ( P <0.01 all).<br />Conclusion: The low concentration contrast agent combined double low dose in CT pulmonary angiography satisfies clinical diagnostic requirements. It has good clinical value for it could reduce venous pollution,iodine contrast agent and radiation exposure.<br /> (Copyright© by Editorial Board of Journal of Sichuan University (Medical Science Edition).)

Details

Language :
Chinese
ISSN :
1672-173X
Volume :
49
Issue :
2
Database :
MEDLINE
Journal :
Sichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition
Publication Type :
Academic Journal
Accession number :
29737068