Back to Search Start Over

Influence of xenon on pulmonary mechanics and lung aeration in patients with healthy lungs.

Authors :
Schaefer MS
Treschan TA
Gauch J
Neukirchen M
Kienbaum P
Source :
British journal of anaesthesia [Br J Anaesth] 2018 Jun; Vol. 120 (6), pp. 1394-1400. Date of Electronic Publication: 2018 Apr 13.
Publication Year :
2018

Abstract

Background: The anaesthetic xenon shows potent organ-protective properties. Due to high density and dynamic viscosity, peak inspiratory pressure (P <subscript>max</subscript> ) increases during xenon application. Thus, barotrauma may counteract organ protection. Accordingly, we investigated the influence of xenon on lung mechanics and lung aeration in patients with normal and reduced thoracic wall compliance.<br />Methods: After registration and ethical approval, 20 patients free of pulmonary disease undergoing routine xenon-based anaesthesia were mechanically ventilated. The primary outcome variable transpulmonary pressure (P <subscript>tp</subscript> ) was determined from plateau pressure and intraoesophageal pressure before and after xenon wash-in. We recorded P <subscript>max</subscript> , and calculated airway resistance (R <subscript>AW</subscript> ), and static (C <subscript>stat</subscript> ) and dynamic (C <subscript>dyn</subscript> ) respiratory compliances. Finally, lung aeration was quantified by electrical impedance tomography-derived centre of ventilation index (CVI) and global inhomogeneity index (GI) in the awake state, before and during xenon.<br />Results: Xenon increased P <subscript>max</subscript> [20.8 (SD 3) vs 22.6 (3) cm H <subscript>2</subscript> O, P<0.001] and R <subscript>AW</subscript> [0.9 (0.2) vs 1.4 (0.3) cm H <subscript>2</subscript> O litre <superscript>-1</superscript>  s, P<0.001], without affecting P <subscript>tp</subscript> [1.5 (4) vs 2.0 (4) cm H <subscript>2</subscript> O, P=0.15]. While C <subscript>stat</subscript> remained unchanged, C <subscript>dyn</subscript> was reduced [33.9 (7) vs 31.2 (6) ml (cm H <subscript>2</subscript> O) <superscript>-1</superscript> , P<0.001). A ventral tidal volume shift after anaesthesia induction [CVI 0.53 (0.03) vs 0.59 (0.04), P<0.001] was unaltered during xenon [CVI 0.59 (0.04), P=0.29]. Homogeneity of lung aeration was also unchanged during xenon [GI 0.37 (0.03) vs 0.37 (0.03), P=0.99]. There were no clinically meaningful differential BMI-related effects.<br />Conclusions: Xenon increases calculated airway resistance and peak inspiratory pressure without affecting transpulmonary pressure, independent of BMI.<br />Clinical Trial Registration: NCT02682758.<br /> (Copyright © 2018 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.)

Details

Language :
English
ISSN :
1471-6771
Volume :
120
Issue :
6
Database :
MEDLINE
Journal :
British journal of anaesthesia
Publication Type :
Academic Journal
Accession number :
29793604
Full Text :
https://doi.org/10.1016/j.bja.2018.02.064