Time and temperature sensitivity of the Hybrid III neck.
- Source :
-
Traffic injury prevention [Traffic Inj Prev] 2018; Vol. 19 (6), pp. 657-663. Date of Electronic Publication: 2018 Sep 19. - Publication Year :
- 2018
-
Abstract
- The Hybrid III (HIII) dummy is one of the most widely used anthropomorphic test devices (ATDs) in the world, and researchers have found a variety of uses for it outside of its original purpose as an automotive crash test dummy. These expanded roles have introduced situations outside the dummy's original design parameters, where a number of tests must be run in relatively rapid succession or where it may not be possible to control the temperature of the test environment.<br />Objective: This study has 2 aims. The first is to determine how the duration of the time interval between tests affects the axial compression performance of the HIII neck. The second is to quantify the effect of temperature on the neck's compressive stiffness through a range of temperatures relevant to indoor or outdoor testing.<br />Methods: To characterize the effects of different test conditions, a series of high-rate axial compressive tests was run on a 50th percentile male HIII neck component in a materials testing machine. Between-test recovery intervals were varied from 2 h to 1 min, and temperature conditions of 0, 12.5, 25, and 37.5 °C were tested.<br />Results: Though the duration of the recovery interval had little impact on the recorded force (less than 1%), the component did exhibit considerable strain creep over the course of the test. Temperature had a strong influence on the compressive stiffness of the component. Compared to the stiffness at 25 °C (near room temperature), the stiffness of the neck at 37.5 °C fell by 15%; at 0 °C, the stiffness more than doubled.<br />Conclusions: This study demonstrates that though the duration of the recovery interval between tests has a small influence on neck stiffness, temperature effects should not be overlooked because they influence neck compressive stiffness considerably. The relationship between recorded force and temperature is well represented by exponential decay models. These findings highlight the importance of monitoring and controlling for temperature effects during all HIII testing.
- Subjects :
- Accidents, Traffic
Time Factors
Equipment Design
Manikins
Neck
Temperature
Subjects
Details
- Language :
- English
- ISSN :
- 1538-957X
- Volume :
- 19
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Traffic injury prevention
- Publication Type :
- Academic Journal
- Accession number :
- 29927682
- Full Text :
- https://doi.org/10.1080/15389588.2018.1480832