Back to Search Start Over

Subcutaneous implantable cardioverter-defibrillator: is it ready for use in children and young adults? A single-centre study.

Authors :
Silvetti MS
Pazzano V
Verticelli L
Battipaglia I
Saputo FA
Albanese S
Lovecchio M
Valsecchi S
Drago F
Source :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology [Europace] 2018 Dec 01; Vol. 20 (12), pp. 1966-1973.
Publication Year :
2018

Abstract

Aims: Use of the subcutaneous implantable cardioverter-defibrillator (S-ICD) to prevent sudden cardiac death is increasing. Few data exist on S-ICD in young patients. We reviewed our single-centre experience in order to assess the effectiveness and safety of S-ICD implantation, and to identify potential factors associated with complications.<br />Methods and Results: Observational, non-randomized, standard-of-care study on S-ICD implantation/follow-up in young patients with inherited arrhythmias (IA), cardiomyopathies, and congenital heart defects (CHD). Fifteen patients (6 CHD, 8 cardiomyopathies, and 1 IA), median age 15 years (25th-75th centiles, 14-28), 10 of them <18 years, with body mass index (BMI) 22.6 ± 3.4, underwent S-ICD implantation (primary prevention 93%). The first six patients underwent a standard implantation procedure (three surgical incisions), the following nine a two-incision procedure. No intraoperative complications occurred. Over 12 (7-24) months follow-up, two patients received appropriate shocks and one (7%) inappropriate shock. Four patients had device-related complications requiring surgical intervention: three skin erosions at the superior parasternal incision, one pocket infection. A higher risk of complications was seen in patients who underwent standard procedures [hazard ratio (HR) 4.98, 95% confidence interval (CI) 1.53-47.36; P = 0.0482] and those with BMI <20 (HR 9.44, 95% CI 0.95-93.23; P = 0.0169).<br />Conclusion: S-ICD implantation was safe and effective in young patients with low rates of inappropriate shock. However, the risk of device-related complications during follow-up remains substantial in patients with low BMI. To prevent possible complications, a two-incision technique should be preferred.

Details

Language :
English
ISSN :
1532-2092
Volume :
20
Issue :
12
Database :
MEDLINE
Journal :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
Publication Type :
Academic Journal
Accession number :
29939256
Full Text :
https://doi.org/10.1093/europace/euy139