Back to Search
Start Over
A comparison of physical activity from Actigraph GT3X+ accelerometers worn on the dominant and non-dominant wrist.
- Source :
-
Clinical physiology and functional imaging [Clin Physiol Funct Imaging] 2019 Jan; Vol. 39 (1), pp. 51-56. Date of Electronic Publication: 2018 Jul 30. - Publication Year :
- 2019
-
Abstract
- The purpose of this study was to evaluate the agreement between several activity measures using raw acceleration data from accelerometers worn concurrently on the dominant and non-dominant wrist. Fifty-five adults (31·9 ± 9·7 years, 26 males) wore two ActiGraph GT3X+ monitors continuously for 1 day, one on their non-dominant wrist and the other on their dominant wrist. Paired t-tests were undertaken with sequential Holm-Bonferroni corrections to compare wear time, moderate-vigorous physical activity (MVPA), time spent in 10-min bouts of MVPA (MVPA <subscript>10 min</subscript> ) and the average magnitude of dynamic wrist acceleration (ENMO). Level of agreement between outcome variables from the wrists was examined using intraclass correlation coefficients (ICC, single measures, absolute agreement) with 95% confidence intervals and limits of agreement (LoA). Time spent across acceleration levels in 40 mg resolution were also examined. There were no significant differences between the non-dominant and dominant wrist for ENMO, wear time, MVPA or MVPA <subscript>10 min</subscript> . Agreement between wrists was strong for most outcomes (ICC ≥0·92) including wear time, ENMO, MVPA, MVPA <subscript>10 min</subscript> and the distribution of time across acceleration levels. Agreement was strong in the low acceleration bands (ICC = 0·970 and 0·922) with a mean bias of 3·08 min (LoA -55·18 to 61·34) and -5·43 (LoA -43·47 to 32·62). In summary, ENMO, MVPA, MVPA <subscript>10 min</subscript> , wear time and the distribution of time across acceleration levels compared well at the group level. The LOA from the two lowest acceleration levels suggest further work over a longer monitoring period is needed to determine whether outputs from each wrist are comparable.<br /> (© 2018 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.)
Details
- Language :
- English
- ISSN :
- 1475-097X
- Volume :
- 39
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Clinical physiology and functional imaging
- Publication Type :
- Academic Journal
- Accession number :
- 30058765
- Full Text :
- https://doi.org/10.1111/cpf.12538