Unenhanced Velocity-Selective MR Angiography (VS-MRA): Initial Clinical Evaluation in Patients With Peripheral Artery Disease.

Authors :
Shin T
Menon RG
Thomas RB
Cavallo AU
Sarkar R
Crawford RS
Rajagopalan S
Source :
Journal of magnetic resonance imaging : JMRI [J Magn Reson Imaging] 2019 Mar; Vol. 49 (3), pp. 744-751. Date of Electronic Publication: 2018 Sep 13.
Publication Year :
2019

Abstract

Background: Safe and accurate imaging of the peripheral arterial system is important for diagnosis and treatment planning of patients with peripheral artery disease (PAD).<br />Purpose: To evaluate image quality and diagnostic performance of unenhanced magnetic resonance angiography (MRA) based on velocity-selective (VS) magnetization preparation (termed VS-MRA).<br />Study Type: Prospective.<br />Population: Thirty-one symptomatic PAD patients underwent VS-MRA. Twenty-four of them underwent clinical digital subtraction angiography (DSA) examination, 18.8 ± 5.2 days after the MR scans.<br />Field Strength/sequence: 1.5T MRI that included VS-MRA (homemade research sequence) and phase-contrast flow imaging (clinical sequence).<br />Assessment: Image quality (0: nondiagnostic, 3: excellent) and stenosis severity (0: normal, 3: occlusion) of VS-MRA images were assessed independently by three reviewers. Arterial signal-to-noise-ratio (SNR) and artery-to-muscle contrast-to-noise ratio (CNR) were calculated.<br />Statistical Tests: The sensitivity and specificity of VS-MRA were calculated for the detection of significant stenosis (>50%) with DSA as the reference standard. Interobserver agreement among the three reviewers was evaluated by using Cohen κ-statistics.<br />Results: The image quality score of VS-MRA was 2.7 ± 0.5 for Reader 1, 2.8 ± 0.5 for Reader 2, and 2.8 ± 0.4 for Reader 3; SNR and CNR were 37.8 ± 12.5 and 30.5 ± 11.8, respectively. Segment-based analysis revealed that VS-MRA had sensitivities of 85.3%, 74.5%, and 78.4%, respectively, for the three reviewers, and specificities of 93.5%, 96.8%, and 95.2%. The interobserver agreement for the stenosis grading was good, as demonstrated by Cohen κ values of 0.76 (Reader 1 vs. Reader 2), 0.82 (Reader 1 vs. Reader 3), and 0.79 (Reader 2 vs. Reader 3).<br />Data Conclusion: Unenhanced VS-MRA allows clear depiction of the peripheral arteries and accurate stenosis grading, as evidenced by high image quality scores and strong agreement with DSA.<br />Level of Evidence: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:744-751.<br /> (© 2018 International Society for Magnetic Resonance in Medicine.)

Details

Language :
English
ISSN :
1522-2586
Volume :
49
Issue :
3
Database :
MEDLINE
Journal :
Journal of magnetic resonance imaging : JMRI
Publication Type :
Academic Journal
Accession number :
30211442
Full Text :
https://doi.org/10.1002/jmri.26268