Back to Search Start Over

Titanium as a modifier of the peri-implant microbiome structure.

Authors :
Daubert D
Pozhitkov A
McLean J
Kotsakis G
Source :
Clinical implant dentistry and related research [Clin Implant Dent Relat Res] 2018 Dec; Vol. 20 (6), pp. 945-953. Date of Electronic Publication: 2018 Sep 25.
Publication Year :
2018

Abstract

Background: Recent data support the implication of accelerated titanium dissolution products in peri-implantitis. It is unknown whether these dissolution products have an effect on the peri-implant microbiome, the target of existing peri-implantitis therapies.<br />Purpose: This study assessed the relationship between the peri-implant microbiome, dissolved titanium levels, and peri-implantitis.<br />Materials and Methods: Clinical, microbiome, and titanium data were collected from a periodontal population having implants in function for 10 years. Clinical examinations were performed, and submucosal plaque samples were collected from the deepest site per implant. An aliquot of the sample was used for 16S rRNA gene sequencing, with the remainder analyzed for titanium quantity using mass spectrometry. Sequences were clustered into taxonomic units at 97% minimum sequence similarity using the QIIME pipeline approach.<br />Results: Fifteen implants were assessed. According to established case definitions, six had a diagnosis of peri-implantitis; nine were healthy. The genera Streptococcus, Prevotella and Haemophilus characterized peri-implant health. Peri-implantitis was associated with a marked increase in Veillonella. Quantities of dissolved titanium were identified in 40% of sites. Titanium presence was associated with peri-implant disease status (P = .02) and correlated to the first principal component of the microbiome (rho = 0.552) and its alpha-diversity (rho = -0.496). Canonical correlation analyses found that titanium levels, but not health or disease status of the implant, were significantly associated with the microbiota composition (P = .045).<br />Conclusions: These findings suggest an association between titanium dissolution products and peri-implantitis and support a role for these products in modifying the peri-implant microbiome structure and diversity.<br /> (© 2018 Wiley Periodicals, Inc.)

Details

Language :
English
ISSN :
1708-8208
Volume :
20
Issue :
6
Database :
MEDLINE
Journal :
Clinical implant dentistry and related research
Publication Type :
Academic Journal
Accession number :
30255621
Full Text :
https://doi.org/10.1111/cid.12676