Back to Search
Start Over
In vitro flow and optical coherence tomography comparison of two bailout techniques after failed provisional stenting for bifurcation percutaneous coronary interventions.
- Source :
-
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions [Catheter Cardiovasc Interv] 2019 Jan 01; Vol. 93 (1), pp. E8-E16. Date of Electronic Publication: 2018 Oct 23. - Publication Year :
- 2019
-
Abstract
- Objectives: To evaluate, in vitro, SB stenting techniques after failed provisional stenting. We aimed to compare flows and stent strut apposition of T and protrusion (TAP) versus Reversed String (RS) techniques using a flow simulator, optical coherence tomography (OCT) using silicon bifurcation phantoms with different bifurcation angulations.<br />Background: While bifurcation coronary artery stenoses are preferably treated with provisional T-stenting strategy, the preferred bailout two stents technique to treat the side branch remains unclear.<br />Methods and Results: Eleven 30°-angle and ten 60°-angle bifurcation phantoms were used. After performing provisional stenting, TAP and RS techniques were compared in six phantoms with 30° and five with 60° angles. Flow measurement was performed using absolute coronary flow and particle image velocimetry techniques. Strut apposition was evaluated using OCT. Flow analyses showed that disturbed flow regions were observed in the vicinity of floating struts protruded into the lumen both regardless of TAP and RS techniques. OCT analysis showed a higher proportion of floating struts protruding into the main branch with TAP compared to RS, respectively (13% vs. 1%; P <0.001) in both angles.<br />Conclusions: RS reduces the proportion of floating struts protruding into the main branch compared to TAP, at comparable flow rates. Clinical studies are needed to evaluate feasibility and potential clinical benefit of this technique.<br /> (© 2018 Wiley Periodicals, Inc.)
- Subjects :
- Angioplasty, Balloon, Coronary adverse effects
Blood Flow Velocity
Coronary Stenosis diagnostic imaging
Coronary Stenosis physiopathology
Coronary Vessels physiopathology
Models, Anatomic
Models, Cardiovascular
Predictive Value of Tests
Proof of Concept Study
Silicon
Treatment Failure
Angioplasty, Balloon, Coronary instrumentation
Coronary Circulation
Coronary Stenosis therapy
Coronary Vessels diagnostic imaging
Drug-Eluting Stents
Retreatment methods
Rheology methods
Tomography, Optical Coherence
Subjects
Details
- Language :
- English
- ISSN :
- 1522-726X
- Volume :
- 93
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
- Publication Type :
- Academic Journal
- Accession number :
- 30351495
- Full Text :
- https://doi.org/10.1002/ccd.27718