Back to Search Start Over

Analytical Eco-Scale for Assessing the Greenness of a Developed Potentiometric Method for Lomefloxacin Hydrochloride Determination in its Different Dosage Forms, Plasma, and Dissolution Medium.

Authors :
Boltia SA
Soudi AT
Elzanfaly ES
Zaazaa HE
Source :
Journal of AOAC International [J AOAC Int] 2019 May 01; Vol. 102 (3), pp. 794-800. Date of Electronic Publication: 2018 Nov 16.
Publication Year :
2019

Abstract

Background: Traditional methods for Lomefloxacin hydrochloride (LOM) determination involve pretreatment steps, which extend analysis time and use hazardous chemicals. Objective: The ability to provide a rapid route without sample pretreatment for quantitative determination of compounds via a low-cost instrument is a challenging task. In this work, a simple potentiometric method was developed to determine the antibacterial LOM via in-house fabricated ion selective electrodes. Methods: Different sensors were fabricated using a poly vinyl chloride-based membrane, potassium tetrakis(4-chlorophenyl) borate as a cation exchanger, and 2-Nitrophenyl octyl ether as a plasticizer (sensor 1). To increase the selectivity of sensor 1, a selective molecular recognition component 2-hydroxypropyl-β-cyclodextrin was used as ionophore (sensor 2). Results: The proposed method was validated according to International Union of Pure and Applied Chemistry recommendations, in which the proposed sensors show a linear dynamic range from 1 × 10 <superscript>-5</superscript> to 1 × 10 <superscript>-2</superscript> mol/L, with Nernstian slopes of 55.829 and 58.229 mV/decade for sensors 1 and 2, respectively. It was applied to determine LOM in bulk powder, in different dosage forms, and in plasma with no sample pretreatment. Also, the suggested method can be used as a green, in-line bench top real-time analyzer for in-process monitoring of LOM release from its tablets, under U.S. Food and Drug Administration dissolution regulations, with clear discrimination from common excipients. Results obtained by the proposed potentiometric method were compared with those obtained by a reported HPLC method. Conclusions: The proposed method is considered as a perfect alternative to traditional reported methods for LOM determination.

Details

Language :
English
ISSN :
1944-7922
Volume :
102
Issue :
3
Database :
MEDLINE
Journal :
Journal of AOAC International
Publication Type :
Academic Journal
Accession number :
30446018
Full Text :
https://doi.org/10.5740/jaoacint.18-0217