Back to Search Start Over

In vivo confocal microscopy morphometric analysis of corneal subbasal nerve plexus in dry eye disease using newly developed fully automated system.

Authors :
Giannaccare G
Pellegrini M
Sebastiani S
Moscardelli F
Versura P
Campos EC
Source :
Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie [Graefes Arch Clin Exp Ophthalmol] 2019 Mar; Vol. 257 (3), pp. 583-589. Date of Electronic Publication: 2019 Jan 14.
Publication Year :
2019

Abstract

Purpose: To evaluate in vivo confocal microscopy (IVCM) features of corneal subbasal nerve plexus (SNP) in the setting of dry eye disease (DED) using fully automated software "ACCMetrics," and to further investigate its diagnostic performance in discriminating DED patients.<br />Methods: IVCM exams of SNP in DED patients and matched control subjects were performed using Heidelberg Retina Tomograph with the Rostock Cornea Module. The following parameters were obtained with ACCMetrics: corneal nerve fiber density (CNFD), corneal nerve branch density (CNBD), corneal nerve fiber length (CNFL), corneal nerve total branch density (CTBD), corneal nerve fiber area (CNFA), corneal nerve fiber width (CNFW), and corneal nerve fractal dimension (CNFrD). The Mann-Whitney U test was used to compare variables. Receiver operating characteristic curves with calculations of the area under the curve (AUC) were used to describe the accuracy of IVCM parameters for discriminating DED patients from controls.<br />Results: Thirty-nine DED patients and 30 control subjects were included. Significantly, lower values of CNFD, CNBD, and CNFL and higher value of CNFW were found in DED patients compared to controls (respectively, 20.5 ± 8.7 vs 25.4 ± 6.7 n/mm <superscript>2</superscript> ; 25.6 ± 20.1 vs 37.6 ± 21.5 n/mm <superscript>2</superscript> ; 12.6 ± 4.4 vs 14.5 ± 2.9 mm/mm <superscript>2</superscript> ; 0.021 ± 0.001 vs 0.019 ± 0.001 mm/mm <superscript>2</superscript> ; always p < 0.024). CNFW value had the highest diagnostic power in discriminating DED patients (AUC = 0.828). When the diagnosis of DED was made based on either CNFW or CNBD, the sensitivity was 97.4% and the specificity 46.7%.<br />Conclusions: The software ACCMetrics was able to rapidly detect SNP alterations occurring in the setting of DED and showed good diagnostic performance in discriminating DED patients.

Details

Language :
English
ISSN :
1435-702X
Volume :
257
Issue :
3
Database :
MEDLINE
Journal :
Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie
Publication Type :
Academic Journal
Accession number :
30637452
Full Text :
https://doi.org/10.1007/s00417-018-04225-7