Evaluation of ventricular septal defects using high pitch computed tomography angiography of the chest in children with complex congenital heart defects below one year of age.
- Source :
-
Journal of cardiovascular computed tomography [J Cardiovasc Comput Tomogr] 2019 Jul - Aug; Vol. 13 (4), pp. 226-233. Date of Electronic Publication: 2019 Feb 01. - Publication Year :
- 2019
-
Abstract
- Background: Aim of this study was to assess the accuracy of ventricular septal defects (VSD) using high pitch computed tomography angiography (CTA) of the chest in children below 1 year of age, compared to the intraoperative findings and echocardiography.<br />Methods: Out of 154 patients that underwent Dual-Source CTA of the chest using a high-pitch protocol at low tube voltages (70-80 kV), 55 underwent surgical repair of a VSD (median age 8 days, range 1-348 days). The margins of the VSDs and their relation to the surrounding structures were reproduced by en-face views using multiplanar reformations (MPR). Absolute diameter, normalized area and relative area compared to the aortic valve annulus were used for discrimination between restrictive and non-restrictive defects. Localization was classified into four subtypes. The results were compared to two-dimensional echocardiography and intraoperative findings.<br />Results: Median absolute size of VSDs did not differ significantly between CTA-measurements (10.8 mm, range 2.8-18.1 mm) and intraoperative findings (12.0 mm, 3.0-25.0 mm, p = 0.09). Echocardiographic values were significantly lower (9.6 mm, 3.0-18.5 mm, both p < 0.01). The classification of the location and orientation matched the intraoperative situs in 96.4% of all cases using CT and in 87.3% using echocardiography. Echocardiography missed the relation to valves in 11% of all cases. Pre-interventional sensitivity and specificity for detection of a VSD were 97.2/98.9% compared to echocardiography. Median radiation dose was 0.32 mSv (range 0.12-2.00 mSv) and differed significantly between second and third generation Dual-Source CT (0.43 vs. 0.22 mSv, p = 0.003).<br />Conclusion: Size and subtype of VSDs can be accurately assessed by CTA of the chest in patients with complex congenital heart defects at a very low radiation dose.<br /> (Copyright © 2019 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Age Factors
Echocardiography
Heart Septal Defects, Ventricular surgery
Humans
Infant
Infant, Newborn
Predictive Value of Tests
Radiation Dosage
Radiation Exposure
Reproducibility of Results
Retrospective Studies
Computed Tomography Angiography
Coronary Angiography methods
Heart Septal Defects, Ventricular diagnostic imaging
Subjects
Details
- Language :
- English
- ISSN :
- 1876-861X
- Volume :
- 13
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Journal of cardiovascular computed tomography
- Publication Type :
- Academic Journal
- Accession number :
- 30737152
- Full Text :
- https://doi.org/10.1016/j.jcct.2019.01.023