Back to Search
Start Over
One-year clinical outcome of biodegradable polymer sirolimus-eluting stent in patients needing short dual antiplatelet therapy. Insight from the ULISSE registry (ULtimaster Italian multicenter all comerS Stent rEgistry).
- Source :
-
International journal of cardiology [Int J Cardiol] 2019 Sep 01; Vol. 290, pp. 52-58. Date of Electronic Publication: 2019 Mar 17. - Publication Year :
- 2019
-
Abstract
- Background: This study aimed to evaluate real-world clinical outcome of patients needing short dual antiplatelet therapy (S-DAPT) following PCI with Ultimaster® thin-strut, biodegradable polymer sirolimus-eluting stent (BP-SES), which was supposed to induce faster stent endothelialization and reduce device thrombogenicity.<br />Methods: In this sub-group analysis of patients enrolled in the ULISSE registry, two groups were identified: 1) patients discharged with S-DAPT (≤3-month) due to high bleeding risk or need for urgent major non-cardiac surgery and 2) patients discharged with recommended DAPT (R-DAPT) duration (≥6-month). The primary ischemic-safety and bleeding-safety endpoints were TLF (composite of cardiac-death, target vessel MI, and clinically driven target lesion revascularization), and BARC major bleedings (≥type-3a) at 1-year follow-up. To account for events occurring before DAPT discontinuation we performed 3-month landmark analysis.<br />Results: 82 patients (5%) were discharged with ≤3-month DAPT (57 ± 27 days), and 1558 patients (94%) were discharged with ≥6-month DAPT (318 ± 75 days). No significant differences between S-DAPT and R-DAPT group were observed in TLF at 1-year (7.9% vs. 4.6%). The rate of BARC major bleeding resulted significantly higher in S-DAPT group (3.9% vs. 0.3%; p = 0.001), with the majority of bleeding events occurring within 3 months. The landmark analysis showed no significant differences in BARC major bleedings between groups (1.4% vs. 0.3%; p = 0.142).<br />Conclusions: As compared to those treated with R-DAPT (≥6-month), patients needing -S-DAPT (≤3-month) after PCI with Ultimaster® BP-SES had similar rates of 1-year TLF and BARC major bleedings following early DAPT discontinuation.<br /> (Copyright © 2019 Elsevier B.V. All rights reserved.)
- Subjects :
- Acute Coronary Syndrome diagnostic imaging
Acute Coronary Syndrome epidemiology
Aged
Aged, 80 and over
Follow-Up Studies
Humans
Immunosuppressive Agents administration & dosage
Italy epidemiology
Middle Aged
Polymers
Retrospective Studies
Time Factors
Treatment Outcome
Absorbable Implants trends
Acute Coronary Syndrome therapy
Drug-Eluting Stents trends
Platelet Aggregation Inhibitors administration & dosage
Registries
Sirolimus administration & dosage
Subjects
Details
- Language :
- English
- ISSN :
- 1874-1754
- Volume :
- 290
- Database :
- MEDLINE
- Journal :
- International journal of cardiology
- Publication Type :
- Academic Journal
- Accession number :
- 30917900
- Full Text :
- https://doi.org/10.1016/j.ijcard.2019.03.030