Back to Search Start Over

Standardized volumetric plaque quantification and characterization from coronary CT angiography: a head-to-head comparison with invasive intravascular ultrasound.

Authors :
Matsumoto H
Watanabe S
Kyo E
Tsuji T
Ando Y
Otaki Y
Cadet S
Gransar H
Berman DS
Slomka P
Tamarappoo BK
Dey D
Source :
European radiology [Eur Radiol] 2019 Nov; Vol. 29 (11), pp. 6129-6139. Date of Electronic Publication: 2019 Apr 26.
Publication Year :
2019

Abstract

Objectives: We sought to evaluate the accuracy of standardized total plaque volume (TPV) measurement and low-density non-calcified plaque (LDNCP) assessment from coronary CT angiography (CTA) in comparison with intravascular ultrasound (IVUS).<br />Methods: We analyzed 118 plaques without extensive calcifications from 77 consecutive patients who underwent CTA prior to IVUS. CTA TPV was measured with semi-automated software comparing both scan-specific (automatically derived from scan) and fixed attenuation thresholds. From CTA, %LDNCP was calculated voxels below multiple LDNCP thresholds (30, 45, 60, 75, and 90 Hounsfield units [HU]) within the plaque. On IVUS, the lipid-rich component was identified by echo attenuation, and its size was measured using attenuation score (summed score ∕ analysis length) based on attenuation arc (1 = < 90°; 2 = 90-180°; 3 = 180-270°; 4 = 270-360°) every 1 mm.<br />Results: TPV was highly correlated between CTA using scan-specific thresholds and IVUS (r = 0.943, p < 0.001), with no significant difference (2.6 mm <superscript>3</superscript> , p = 0.270). These relationships persisted for calcification patterns (maximal IVUS calcium arc of 0°, < 90°, or ≥ 90°). The fixed thresholds underestimated TPV (- 22.0 mm <superscript>3</superscript> , p < 0.001) and had an inferior correlation with IVUS (p < 0.001) compared with scan-specific thresholds. A 45-HU cutoff yielded the best diagnostic performance for identification of lipid-rich component, with an area under the curve of 0.878 vs. 0.840 for < 30 HU (p = 0.023), and corresponding %LDNCP resulted in the strongest correlation with the lipid-rich component size (r = 0.691, p < 0.001).<br />Conclusions: Standardized noninvasive plaque quantification from CTA using scan-specific thresholds correlates highly with IVUS. Use of a < 45-HU threshold for LDNCP quantification improves lipid-rich plaque assessment from CTA.<br />Key Points: • Standardized scan-specific threshold-based plaque quantification from coronary CT angiography provides an accurate total plaque volume measurement compared with intravascular ultrasound. • Attenuation histogram-based low-density non-calcified plaque quantification can improve lipid-rich plaque assessment from coronary CT angiography.

Details

Language :
English
ISSN :
1432-1084
Volume :
29
Issue :
11
Database :
MEDLINE
Journal :
European radiology
Publication Type :
Academic Journal
Accession number :
31028446
Full Text :
https://doi.org/10.1007/s00330-019-06219-3