Back to Search
Start Over
Impact of Valve Over-Sizing After Transcatheter Aortic Valve Implantation With a Self-Expanding Valve: A Multislice Computed Tomography Study.
- Source :
-
The Journal of invasive cardiology [J Invasive Cardiol] 2019 May; Vol. 31 (5), pp. E76-E82. - Publication Year :
- 2019
-
Abstract
- Background: In transcatheter aortic valve implantation (TAVI), prosthesis over-sizing prevents paravalvular leak (PVL). Strategies of over-sizing for self-expanding bioprostheses are not well established at present.<br />Methods: Patients with aortic valve stenosis scheduled for TAVI underwent preprocedural multislice computed tomography. Based on the degree of over-sizing, a ROC curve was drawn to define the optimal value of valve sizing for reducing PVL after TAVI.<br />Results: A total of 152 consecutive patients were included in the study (mean age, 79.95 ± 7.71 years; log EuroScore: 23.87 ± 8.93%). Based on the ROC curve, sizing of 14% was the optimal that would lead to less moderate/severe PVL (P<.01). Group 1 was defined as sizing <14% (n = 49 patients) and group 2 was defined as sizing ≥14% (n = 103 patients). During a follow-up period of 36 ± 14 months, a total of 9 patients died from group 1 vs 4 patients from group 2 (P<.01). Two of the patients who died had moderate/severe PVL and 11 had no/mild PVL (P=.27). From the population, a total of 49 patients (32%) were found to be in the "borderline" zone. Patients who received the smaller valve had lower mean left ventricular outflow tract diameter (P=.048), higher rate of calcium load (mild: 10 [32%] vs 13 [72%]; moderate: 16 [52%] vs 3 [17%]; severe: 5 [16%] vs 2 [11%]; P=.02) and lower mean of sinus of Valsalva diameter (P=.046) compared with patients who received the bigger valve.<br />Conclusions: In patients undergoing TAVI, over-sizing the prosthesis at least 14% reduces PVL. In borderline cases, taking into consideration additional anatomical parameters may result in low rates of PVL.
- Subjects :
- Aged
Aged, 80 and over
Aortic Valve Stenosis diagnosis
Aortic Valve Stenosis surgery
Female
Greece
Humans
Male
Outcome and Process Assessment, Health Care
Preoperative Care methods
Prosthesis Failure etiology
Severity of Illness Index
Aortic Valve diagnostic imaging
Aortic Valve pathology
Aortic Valve surgery
Aortic Valve Insufficiency diagnosis
Aortic Valve Insufficiency etiology
Aortic Valve Insufficiency prevention & control
Heart Valve Prosthesis adverse effects
Heart Valve Prosthesis standards
Multidetector Computed Tomography methods
Multidetector Computed Tomography statistics & numerical data
Postoperative Complications diagnosis
Postoperative Complications etiology
Postoperative Complications prevention & control
Transcatheter Aortic Valve Replacement adverse effects
Transcatheter Aortic Valve Replacement instrumentation
Transcatheter Aortic Valve Replacement methods
Subjects
Details
- Language :
- English
- ISSN :
- 1557-2501
- Volume :
- 31
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- The Journal of invasive cardiology
- Publication Type :
- Academic Journal
- Accession number :
- 31034438