Back to Search
Start Over
Validation of a sensitive simultaneous LC-MS/MS method for the quantification of novel anti-cancer thiazolidinedione and quinazolin-4-one derivatives in rat plasma and its application in a rat pharmacokinetic study.
- Source :
-
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences [J Chromatogr B Analyt Technol Biomed Life Sci] 2019 Jul 15; Vol. 1121, pp. 18-27. Date of Electronic Publication: 2019 May 07. - Publication Year :
- 2019
-
Abstract
- Thiazolidinediones and quinazolin-4-ones compounds, previously known for their activity against Type 2 diabetes and antifungal activity respectively, are currently being investigated for their anti-cancer activity. The determination of pharmacokinetic parameters for these two classes of compounds using a simultaneous chromatographic method with a low detection limit is a challenge. In this study, a highly sensitive and simultaneous LC-MS/MS-based bioanalytical method was developed and validated in rat plasma for the estimation of four novel anti-cancer compounds, BIT-15-67 and BNT-11, belonging to the Thiazolidinedione class, and BNUA-108 and BNUA-48, from the quinazolin-4-one class. The analytes were extracted from plasma samples by protein precipitation and separated on a short reverse phase Hypersil Phenyl BDS, 50 × 4.6 mm, 2.4 μm column at a column oven temperature of 40 °C. An isocratic mobile phase, a 20:80 (v/v) mixture of 5 mM ammonium acetate solution and acetonitrile containing 0.1% formic acid, was used for the elution at a flow rate of 0.4 mL/min. The analytes and internal standard, sulfaphenazole, were quantified in the multiple reaction monitoring mode using positive electrospray ionization with specific pair of mass by charge ratio. All standard validation parameters were assessed as per current bioanalytical method validation guidelines in rat plasma. The area response for the four analytes was found to be linear over the concentration range of 1.00 to 1000 ng/mL in rat plasma. The signal to noise at LLOQ of 1 ng/mL was adequate for application to different pre-clinical studies. The intra- and inter-day precision were <11% and accuracy deviated -1.8 to 9.60% from the nominal. The mean recovery was high (about 90%) and consistent for all the analytes over the linear dynamic range of the method. This simple, robust and validated method can be employed to determine the rat plasma concentrations of the four selected anticancer compounds in preclinical studies such as the pharmacodynamic and the pharmacokinetic studies including tissue distribution and excretion, and the toxicokinetic studies. In this study, pharmacokinetic parameters were determined using this method for all the four compounds individually following intravenous administration in rats.<br /> (Copyright © 2019 Elsevier B.V. All rights reserved.)
- Subjects :
- Animals
Antineoplastic Agents chemistry
Antineoplastic Agents pharmacokinetics
Limit of Detection
Linear Models
Male
Quinazolinones chemistry
Quinazolinones pharmacokinetics
Rats
Rats, Wistar
Reproducibility of Results
Thiazolidinediones chemistry
Thiazolidinediones pharmacokinetics
Antineoplastic Agents blood
Chromatography, Liquid methods
Quinazolinones blood
Tandem Mass Spectrometry methods
Thiazolidinediones blood
Subjects
Details
- Language :
- English
- ISSN :
- 1873-376X
- Volume :
- 1121
- Database :
- MEDLINE
- Journal :
- Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
- Publication Type :
- Academic Journal
- Accession number :
- 31082683
- Full Text :
- https://doi.org/10.1016/j.jchromb.2019.05.003