Back to Search
Start Over
Safety and performance of a novel articulating cage for transforaminal lumbar interbody fusion in the setting of intraoperative spinal navigation.
- Source :
-
Clinical neurology and neurosurgery [Clin Neurol Neurosurg] 2019 Aug; Vol. 183, pp. 105391. Date of Electronic Publication: 2019 Jun 20. - Publication Year :
- 2019
-
Abstract
- Objective: Transforaminal lumbar interbody fusion (TLIF) has been described as safe and effective procedure for the treatment of low back pain. However, only a few retrospective articles describing articulating cages exist in literature. The aim of this study was to assess the clinical and radiological results, as well as patient safety and complications by using a novel articulating TLIF cage.<br />Patients and Methods: Out of 50 patients, 49 were included in this prospective study. Under computer tomography (CT) guided spinal navigation the TLIF procedure was performed. Clinical outcome scores visual analog scale (VAS), Oswestry disability index (ODI) and short form-36 health survey questionnaire (SF-36) were obtained preoperatively, 6 and 12 months after surgery. Radiological data were acquired preoperatively, after 6 weeks, as well as 6 and 12 postoperatively and included measurements for disc height (anterior/posterior), foraminal height, segmental and global lumbar lordosis.<br />Results: 71% of the included patients have undergone previous lumbar surgery. In total, 80 SYNCHRO® cages have been implanted. The clinical results revealed a highly significant improvement of VAS, ODI and SF-36 after 6 and 12 months, compared to baseline levels (p < 0.05). Radiological analysis revealed a significant increase in anterior and posterior disc height, foraminal height, segmental and global lumbar lordosis postoperatively (p < 0.05). 47 out 49 patients (96%) showed evidence for fusion at the 12 months follow-up. Cage dislocation was found in 1 of 80 implanted cages (1%), which required revision surgery. Two dural tears occurred intraoperatively, which have been fixed. Another two patients needed surgical revision due to infection. The overall complication rate was 10% (n = 5/49).<br />Conclusions: The current study delineates satisfactory clinical and radiological results by using a novel articulating TLIF-cage. The implant-related complication rate was acceptable with low revision rate.<br /> (Copyright © 2019 Elsevier B.V. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1872-6968
- Volume :
- 183
- Database :
- MEDLINE
- Journal :
- Clinical neurology and neurosurgery
- Publication Type :
- Academic Journal
- Accession number :
- 31254909
- Full Text :
- https://doi.org/10.1016/j.clineuro.2019.105391