Back to Search Start Over

Evaluation of a motion-robust 2D chemical shift-encoded technique for R2* and field map quantification in ferumoxytol-enhanced MRI of the placenta in pregnant rhesus macaques.

Authors :
Zhu A
Reeder SB
Johnson KM
Nguyen SM
Golos TG
Shimakawa A
Muehler MR
Francois CJ
Bird IM
Fain SB
Shah DM
Wieben O
Hernando D
Source :
Journal of magnetic resonance imaging : JMRI [J Magn Reson Imaging] 2020 Feb; Vol. 51 (2), pp. 580-592. Date of Electronic Publication: 2019 Jul 05.
Publication Year :
2020

Abstract

Background: 3D chemical shift-encoded (CSE)-MRI techniques enable assessment of ferumoxytol concentration but are unreliable in the presence of motion.<br />Purpose: To evaluate a motion-robust 2D-sequential CSE-MRI for R2* and B0 mapping in ferumoxytol-enhanced MRI of the placenta.<br />Study Type: Prospective.<br />Animal Model: Pregnant rhesus macaques.<br />Field Strength/sequence: 3.0T/CSE-MRI.<br />Assessment: 2D-sequential CSE-MRI was compared with 3D respiratory-gated CSE-MRI in placental imaging of 11 anesthetized animals at multiple timepoints before and after ferumoxytol administration, and in ferumoxytol phantoms (0 μg/mL-440 μg/mL). Motion artifacts of CSE-MRI in 10 pregnant women without ferumoxytol administration were assessed retrospectively by three blinded readers (4-point Likert scale). The repeatability of CSE-MRI in seven pregnant women was also prospectively studied.<br />Statistical Tests: Placental R2* and boundary B0 field measurements (ΔB0) were compared between 2D-sequential and 3D respiratory-gated CSE-MRI using linear regression and Bland-Altman analysis.<br />Results: In phantoms, a slope of 0.94 (r <superscript>2</superscript> = 0.99, concordance correlation coefficient ρ = 0.99), and bias of -4.8 s <superscript>-1</superscript> (limit of agreement [LOA], -41.4 s <superscript>-1</superscript> , +31.8 s <superscript>-1</superscript> ) in R2*, and a slope of 1.07 (r <superscript>2</superscript> = 1.00, ρ = 0.99) and bias of 11.4 Hz (LOA -12.0 Hz, +34.8 Hz) in ΔB0 were obtained in 2D CSE-MRI compared with 3D CSE-MRI for reference R2* ≤390 s <superscript>-1</superscript> . In animals, a slope of 0.92 (r <superscript>2</superscript> = 0.97, ρ = 0.98) and bias of -2.2 s <superscript>-1</superscript> (LOA -55.6 s <superscript>-1</superscript> , +51.3 s <superscript>-1</superscript> ) in R2*, and a slope of 1.05 (r <superscript>2</superscript> = 0.95, ρ = 0.97) and bias of 0.4 Hz (LOA -9.0 Hz, +9.7 Hz) in ΔB0 were obtained. In humans, motion-impaired R2* maps in 3D CSE-MRI (Reader 1: 1.8 ± 0.6, Reader 2: 1.3 ± 0.7, Reader 3: 1.9 ± 0.6), while 2D CSE-MRI was motion-free (Reader 1: 2.9 ± 0.3, Reader 2: 3.0 ± 0, Reader 3: 3.0 ± 0). A mean difference of 0.66 s <superscript>-1</superscript> and coefficient of repeatability of 9.48 s <superscript>-1</superscript> for placental R2* were observed in the repeated 2D CSE-MRI.<br />Data Conclusion: 2D-sequential CSE-MRI provides accurate R2* and B0 measurements in ferumoxytol-enhanced placental MRI of animals in the presence of respiratory motion, and motion-robustness in human placental imaging.<br />Level of Evidence: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;51:580-592.<br /> (© 2019 International Society for Magnetic Resonance in Medicine.)

Details

Language :
English
ISSN :
1522-2586
Volume :
51
Issue :
2
Database :
MEDLINE
Journal :
Journal of magnetic resonance imaging : JMRI
Publication Type :
Academic Journal
Accession number :
31276263
Full Text :
https://doi.org/10.1002/jmri.26849