Back to Search
Start Over
Agreement on endoscopic ultrasonography-guided tissue specimens: Comparing a 20-G fine-needle biopsy to a 25-G fine-needle aspiration needle among academic and non-academic pathologists.
- Source :
-
Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society [Dig Endosc] 2019 Nov; Vol. 31 (6), pp. 690-697. Date of Electronic Publication: 2019 Jul 10. - Publication Year :
- 2019
-
Abstract
- Background and Aim: A recently carried out randomized controlled trial showed the benefit of a novel 20-G fine-needle biopsy (FNB) over a 25-G fine-needle aspiration (FNA) needle. The current study evaluated the reproducibility of these findings among expert academic and non-academic pathologists.<br />Methods: This study was a side-study of the ASPRO (ASpiration versus PROcore) study. Five centers retrieved 74 (59%) consecutive FNB and 51 (41%) FNA samples from the ASPRO study according to randomization; 64 (51%) pancreatic and 61 (49%) lymph node specimens. Samples were re-reviewed by five expert academic and five non-academic pathologists and rated in terms of sample quality and diagnosis. Ratings were compared between needles, expert academic and non-academic pathologists, target lesions, and cytology versus histological specimens.<br />Results: Besides a higher diagnostic accuracy, FNB also provided for a better agreement on diagnosing malignancy (ĸ = 0.59 vs ĸ = 0.76, P < 0.001) and classification according to Bethesda (ĸ = 0.45 vs ĸ = 0.61, P < 0.001). This equally applied for expert academic and non-academic pathologists and for pancreatic and lymph node specimens. Sample quality was also rated higher for FNB, but agreement ranged from poor (ĸ = 0.04) to fair (ĸ = 0.55). Histology provided better agreement than cytology, but only when a core specimen was obtained with FNB (P = 0.004 vs P = 0.432).<br />Conclusion: This study shows that the 20-G FNB outperforms the 25-G FNA needle in terms of diagnostic agreement, independent of the background and experience of the pathologist. This endorses use of the 20-G FNB needle in both expert and lower volume EUS centers.<br /> (© 2019 The Authors. Digestive Endoscopy published by John Wiley & Sons Australia, Ltd on behalf of Japan Gastroenterological Endoscopy Society.)
Details
- Language :
- English
- ISSN :
- 1443-1661
- Volume :
- 31
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society
- Publication Type :
- Academic Journal
- Accession number :
- 31290176
- Full Text :
- https://doi.org/10.1111/den.13424