Back to Search
Start Over
Evaluation of the Activity of Heparin Injected into the Fully Implantable Catheter for Chemotherapy (Portocath) between Two Moments of Use.
- Source :
-
Annals of vascular surgery [Ann Vasc Surg] 2019 Nov; Vol. 61, pp. 165-169. Date of Electronic Publication: 2019 Jul 20. - Publication Year :
- 2019
-
Abstract
- Background: The aim of this study is to analyze whether heparin, used as a lock in fully implantable catheter for chemotherapy (portocath), maintains its activity even if it remains in the catheter for a long period of time.<br />Methods: According to the institutional protocol, all catheters routinely use the lock solution with 3 mL of heparinized solution after chemotherapy and the time interval between each change as lock in the catheters studied ranged from 7 to 30 days. A total of 25 blood samples from 22 patients with 6 types of neoplasia on chemotherapy or not were collected according to routine, and the 10 mL of liquid contained in the first aspirated reservoir/catheter (corresponding to the lock of the last section), were sent for laboratory analysis for prospectively studied with the following tests: anti-Xa, partially activated thromboplastin time (APTT), thrombin time (TT), reptilase, and thromboelastogram.<br />Results: Heparin activity was found in 96% of the anti-Xa and APTT tests. In relation to TT, 92% presented activity. The reptilase test was performed on 24 samples with significant time reduction in all of them. In the INTEM stage, the thromboelastometry test showed activity in 92% of samples and in the HEPTEM phase there was reduction in time in all samples. In all samples, the heparin activity was found to be independent of the time of use.<br />Conclusions: We can conclude that lock of heparinized solution used in our service in fully implantable central venous catheters for chemotherapy was maintained with active heparin even after a long period of time (up to 30 days), demonstrating that the half-life of the substance within the catheter is greater than its plasma half-life.<br /> (Copyright © 2019 Elsevier Inc. All rights reserved.)
- Subjects :
- Adult
Aged
Anticoagulants adverse effects
Anticoagulants pharmacokinetics
Blood Coagulation Tests
Catheterization, Central Venous adverse effects
Drug Monitoring methods
Female
Half-Life
Heparin adverse effects
Heparin pharmacokinetics
Humans
Male
Middle Aged
Risk Factors
Time Factors
Treatment Outcome
Anticoagulants administration & dosage
Antineoplastic Agents administration & dosage
Catheter Obstruction etiology
Catheterization, Central Venous instrumentation
Catheters, Indwelling
Central Venous Catheters
Heparin administration & dosage
Neoplasms drug therapy
Subjects
Details
- Language :
- English
- ISSN :
- 1615-5947
- Volume :
- 61
- Database :
- MEDLINE
- Journal :
- Annals of vascular surgery
- Publication Type :
- Academic Journal
- Accession number :
- 31336159
- Full Text :
- https://doi.org/10.1016/j.avsg.2019.04.023