Spatially resolved time-of-flight neutron imaging using a scintillator CMOS-camera detector with kHz time resolution.

Authors :
Woracek R
Krzyzagorski M
Markötter H
Kadletz PM
Kardjilov N
Manke I
Hilger A
Source :
Optics express [Opt Express] 2019 Sep 02; Vol. 27 (18), pp. 26218-26228.
Publication Year :
2019

Abstract

We herein report on using a compact and low cost scintillator-camera based neutron detection system for quantitative time-of-flight imaging applications. While powerful pulsed neutron sources emerge and enable unprecedented scientific achievements, one bottleneck is the availability of suitable detectors that provide high count- and high frame- rate capabilities. For imaging applications the achievable spatial resolution/pixel size is obviously another key characteristic. While major effort was so far directed towards the development of neutron counting type imaging detectors, this work demonstrates that a camera based detector system as commonly employed at steady state sources can also be used if a suitable camera is utilized. This is demonstrated at the ESS test beamline (V20) at Helmholtz-Zentrum Berlin by recording the time-of-flight transmission spectrum of steel samples using a CMOS camera at 1 kHz frame rate, revealing the characteristic Bragg edge pattern. This 'simple' setup in the current state presents a useful option of neutron detection and has the potential to overcome many of the existing limitations and could provide a reliable alternative for neutron detector technology in general, given that the camera and scintillator technology keep up the current development speed.

Details

Language :
English
ISSN :
1094-4087
Volume :
27
Issue :
18
Database :
MEDLINE
Journal :
Optics express
Publication Type :
Academic Journal
Accession number :
31510480
Full Text :
https://doi.org/10.1364/OE.27.026218