Back to Search Start Over

Robust automated reading of the skin prick test via 3D imaging and parametric surface fitting.

Authors :
Pineda J
Vargas R
Romero LA
Marrugo J
Meneses J
Marrugo AG
Source :
PloS one [PLoS One] 2019 Oct 21; Vol. 14 (10), pp. e0223623. Date of Electronic Publication: 2019 Oct 21 (Print Publication: 2019).
Publication Year :
2019

Abstract

The conventional reading of the skin prick test (SPT) for diagnosing allergies is prone to inter- and intra-observer variations. Drawing the contours of the skin wheals from the SPT and scanning them for computer processing is cumbersome. However, 3D scanning technology promises the best results in terms of accuracy, fast acquisition, and processing. In this work, we present a wide-field 3D imaging system for the 3D reconstruction of the SPT, and we propose an automated method for the measurement of the skin wheals. The automated measurement is based on pyramidal decomposition and parametric 3D surface fitting for estimating the sizes of the wheals directly. We proposed two parametric models for the diameter estimation. Model 1 is based on an inverted Elliptical Paraboloid function, and model 2 on a super-Gaussian function. The accuracy of the 3D imaging system was evaluated with validation objects obtaining transversal and depth accuracies within ± 0.1 mm and ± 0.01 mm, respectively. We tested the method on 80 SPTs conducted in volunteer subjects, which resulted in 61 detected wheals. We analyzed the accuracy of the models against manual reference measurements from a physician and obtained that the parametric model 2 on average yields diameters closer to the reference measurements (model 1: -0.398 mm vs. model 2: -0.339 mm) with narrower 95% limits of agreement (model 1: [-1.58, 0.78] mm vs. model 2: [-1.39, 0.71] mm) in a Bland-Altman analysis. In one subject, we tested the reproducibility of the method by registering the forearm under five different poses obtaining a maximum coefficient of variation of 5.24% in the estimated wheal diameters. The proposed method delivers accurate and reproducible measurements of the SPT.<br />Competing Interests: AGM, LAR, J. Marrugo and J, Meneses are co-inventors of a patent application related to this study, Dispositivo y método de reconstrucción 3D para la medición de pápulas en la piel. Colombian Patent App. NC2018/0007546; Inventors: Andres G. Marrugo, Lenny A. Romero, Javier Marrugo, Jaime Meneses. Assignee: Universidad Tecnologica de Bolivar, Universidad de Cartagena, Universidad Industrial de Santander. There are no further patents, products in development or marketed products to declare. This does not alter our adherence to all the PLOS ONE policies on sharing data and materials, as detailed online in the guide for authors.

Details

Language :
English
ISSN :
1932-6203
Volume :
14
Issue :
10
Database :
MEDLINE
Journal :
PloS one
Publication Type :
Academic Journal
Accession number :
31634361
Full Text :
https://doi.org/10.1371/journal.pone.0223623